On or after July 1, 1991, no construction may be initiated within the unincorporated limits of the county for any residential building of any type which:
(1) Employs a gravity tank type, flushometer-valve, or flushometer-tank toilet that uses more than an average of 1.6 gallons of water per flush; provided, however, this subsection shall not be applicable to one-piece toilets until July 1, 1992;
(2) Employs a shower head that allows a flow of more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;
(3) Employs a urinal that uses more than an average of 1.0 gallon of water per flush;
(4) Employs a lavatory faucet or lavatory replacement aerator that allows a flow of more than 2.0 gallons of water per minute; or
(5) Employs a kitchen faucet or kitchen replacement aerator that allows a flow of more than 2.5 gallons of water per minute.
Historia
(Code 1993, § 19-52)