The following facilities shall be included in any manufactured home or mobile home to be located or moved within or into any unincorporated area of Brantley County and shall be inspected by the building official, or his assistants. Prior to the owner, dealer or installer obtaining a manufactured home/mobile home safety decal:

(1) Sanitary facilities. Every manufactured home or mobile home shall contain not less than a kitchen sink, lavatory, tub, or shower, and a water closet all in working condition when properly connected to a water and sewer system approved by the Brantley County Health Department. Every plumbing fixture, water and waste pipe shall be in a sanitary working condition free from leaks and obstruction.

(2) Hot and cold water supply. Every manufactured home or mobile home shall have connected to the kitchen sink, lavatory, and tub or shower a supply of both cold water and hot water.

(3) Water heating facilities. Every manufactured home or mobile home shall have water-heating facilities in safe, working condition.

(4) Heating facilities. Every manufactured home or mobile home shall have heating facilities in safe, working condition. Where a central heating system is not provided, each manufactured home/mobile home shall be provided with facilities whereby heating appliances may be connected. Un-vented fuel burning heaters shall be prohibited except for gas heaters listed for un-vented use and the total input rating of the un-vented heaters is less than 30 BTU per hour per cubic feet of room content.

Un-vented fuel burning heaters shall also be prohibited in bedrooms. In lieu of inspecting the heating facilities of a manufactured home or mobile home, the installer, the manufactured home dealer or owner may request a heating inspection by a qualified licensed third party. Written approval by such a person will be accepted as being in compliance with those portions of the safety standards established herein which pertain to heating systems.

(5) Smoke detector. Every manufactured home or mobile home shall be provided with a State of Georgia approved smoke detector installed and tested in accordance with the manufacturer's recommendations and listings.

(6) Windows. Every habitable room excluding bathrooms, kitchens, and hallways shall have at least one window, which can be opened, facing directly to the outdoors, unless the window looks into an enclosed porch with accessible windows and doors.

(7) Ventilation. Every habitable room shall have at least one window or skylight which can be opened, or such other device that will ventilate the room.

(8) Electrical.

a. Distribution panels. Distribution panels shall be installed in compliance with approved listing, complete with required breakers or fuses, with all unused openings covered with blank covers approved and listed for that purpose.

Connection shall be checked for tightness. Panels shall be accessible.

b. Electrical system. The electrical system (switches, receptacles, fixtures, etc.)

shall be properly installed, wired and shall be in working condition. The pre-owned manufactured home or mobile home shall be subjected to an electrical continuity test(s) to assure that all metallic parts are properly bonded.

c. Third party inspection. The manufactured home dealer, installer or owner may, in lieu of inspecting the electrical and heating system of a manufactured home or mobile home, request an electrical inspection by a qualified licensed third party. Written approval by such a person will be accepted by the building official, as compliance with those portions of the safety standards established herein which pertain to the electrical systems.

(9) Exterior walls. The exterior of the home shall be free of loose or rotting boards or timbers and any other conditions, which might admit rain, mold or dampness to the interior portions of the occupied spaces of the home.

(10) Exterior siding. The exterior siding of the home shall be free of rot and rust and all portions firmly attached to home.

(11) Roofs. Roofs shall be structurally sound and have no obvious defects, which might admit rain, or cause mold or dampness to the interior portion of the dwelling.

(12) Interior floors, walls and ceilings. Every floor, interior wall and ceiling shall be in sound condition to prevent the admittance of rain, dampness, mold or the escape of heating and cooling.

(13) Stairs or ramps. Where the means of egress from a manufactured home or mobile home is substantially different from the elevation of the ground, the dealer, installer, pursuant to contract with the owner, or the owner shall construct an appropriate set of stairs or a ramp. All ramps shall be constructed in accordance with the American Disabilities Act.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 6-8-2010, § 5)