Exceptions to the manual adopted in section 46-116 are as follows:
(1) Wherever the term "department" is used in the manual, it shall mean the county board of health.
(2) Section 290-5-26-.03(8) shall read:
"Submission of Plans, Specifications and Soil Data. Plans, specifications and soil data and, if required, percolation test data submitted to the county board of health for the purpose of obtaining a construction permit to install a central onsite sewage management system to serve a commercial, industrial or institutional facility, which will produce a sewage flow in excess of 2,000 gallons per day, a travel trailer and/or mobile home park, or multiple-family dwelling of two or more family units shall bear the registration number and signature of a registered professional engineer, certified and registered under the laws of the State of Georgia. The county board of health may accept plans, specifications, soil data and percolation test data for commercial, industrial or institutional facilities with sewage flows of 2,000 gallons or less per day and for single-family dwellings when prepared in accordance with these rules, from any person who demonstrates to the satisfaction of the county board of health that they have sufficient knowledge of onsite sewage management system design, soil evaluation and of conducting percolation tests."
(3) Replacement area for the drainfield for individual systems and 100 percent replacement for central systems shall be required.
(4) Minimum lot sizes defined in such manual do not apply to lots recorded at the office of the clerk of the superior court as of the date of adoption of the resolution from which this article is derived.
(5) Multifamily dwellings: The county board of health, if it deems necessary, may require separate septic tank systems or grease trap systems for each apartment unit.
(6) All residences having septic tanks are required to have a minimum of 100 feet of nitrification line per bedroom.
(7) All septic tanks will have at least ten feet of solid drain line from the septic tank before beginning the nitrification field.
Historia
(Res. of 6-9-1986)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.