Sec. 70-55. Percolation tests and test boring's.

Sobre este texto

  • As published by Municode, current through 2025-02-04
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Percolation tests. If conducted, percolation tests shall not be considered presumptive or conclusive evidence as to the suitability of a given lot for the use of on-site sewage management systems. Such tests shall be considered and analyzed as one of many criteria in determining soil suitability. Acceptable data on soil characteristics, including the location of rock strata and water

table evaluations, will be considered of primary importance. Percolation tests, if conducted, will be used to augment or supplement the soils data.

It should be further understood that percolation tests conducted during dry weather periods in areas that commonly experience high seasonal water table elevations during wet periods of the year will often exhibit very good percolation rates, thus inaccurately portraying the absorptive capacity of the soil during wet periods. Percolation tests shall be run in accordance with the modified

Taft Engineering Center method published in the department's current manual for on-site sewage management systems.

(b) Location and number.

( 1) Percolation test holes should be located in the area proposed for the installation of the absorption field. Data from test holes in areas outside of, or clearly uncharacteristic of, the proposed installation site will not be allowed. Percolation tests shall not be conducted in holes created by the deterioration of stumps and roots, or any other area

which would render results that inaccurately portray the absorptive capacity of the soil in the absorption field area.

(2) The number of tests shall be sufficient to obtain a proper appraisal of the absorptive capacity of the soH in the proposed absorption field area and shall be determined by the county board of health. The number of

tests required for preliminary appraisal of subdivisions may be specified in lesser numbers, provided a general overview of the soil characteristics of the total subdivision

acreage is provided. Percolation test holes shall be located by number on a topographic map showing lot designation, boundaries, easements, etc., and the results shall be recorded on the map.

(c) Test borings for rock, shale, hardpan. Where surface outcropping or subsurface formations raise reasonable doubt concerning the operational effectiveness of on-site sewage management systems, a sufficient number of test borings to an appropriate depth may be required by the county

board of health to determine whether on-site sewage management systems can be expected to give satisfactory service. Such borings and the results shall be located by number and recorded on the topographic map.

(d) Individuals conducting tests. Individuals conducting percolation tests and/or test borings shall notify the county board of health at least 24 hours prior to performing these procedures and, at the option of the county board of health, such procedures shall be performed in the presence of a county board of health representative.

(Co. Bd. Health Rule 290-5-26.10)