Columbia County · Código de ordenanzas
Part II - CODE OF ORDINANCES / Chapter 18 - BUILDINGS AND BUILDING CONSTRUCTION / Article III - PERMITS
Sec. 18-88. Drawings and specifications.
Sobre este texto
- As published by Municode, current through 2026-02-17
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) When required by the director, two or more copies of specifications and drawings drawn to scale, with sufficient clarity and detail to indicate the nature and character of the work, shall accompany each permit application under this article. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials when quality is essential to conformity with this chapter.
Such information shall be specific, and this chapter shall not be cited as a whole, or in part.
The term "illegal," or its equivalent, shall not be used as a substitute for specific information on a permit application.
(b) The director may require details, computations, stress diagrams and other data necessary to describe the construction and basis of calculations, and such data shall bear the signature of the person responsible for the design thereof.
(c) All drawings, specifications and accompanying data shall bear the name and address of the designer. In the case of buildings or structures of
group E-educational, group I-institutional and group A-assembly occupancy, and all buildings or structures three stories or more in height, or 5,000 square feet in area, except one-family and two-family dwellings, the designer shall be an architect or engineer legally registered under the laws of this state regulating the practice of architecture or engineering, and shall affix his official seal to such drawings, specifications and accompanying data.
(d) Plans for buildings and structures that require approval of the state fire marshal, pursuant to O.C.G.A. § 92A-710, must bear the name and address of the designer, and the designer
shall affix his official seal to such plans.
(e) Plans for all buildings shall indicate how required structural and fire-resistive integrity will be maintained where a penetration for electrical, mechanical, plumbing and communication conduits, pipes and systems shall be made;
and shall also indicate, in sufficient detail, how the fire integrity will be maintained where required fire-resistive floors intersect the exterior walls.