Emanuel County · Código de ordenanzas
Part II - CODE OF ORDINANCES / Chapter 64 - UTILITIES / Article II - SEPTAGE/BULK SEWAGE SLUDGE
Sec. 64-41. Loading rates and disallowed substances at land application sites.
Sobre este texto
- As published by Municode, current through 2025-12-15
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) No industrial or hazardous wastes shall be deposited on the site. Only septage and/or bulk sewage sludge, as defined in this article, is permitted. Prior to land application, all septage and/or bulk sewage sludge shall be screened for removal of municipal solid waste contained in the septage. Any municipal solid waste removed from the septage/bulk sewage sludge shall be disposed of in a lawfully permitted landfill.
(b) No liquid or solid materials removed from a septic tank, cesspool, or similar treatment works that receives either commercial wastewater or industrial wastewater shall be applied on the site, nor shall grease removed from a grease trap at a restaurant.
(c) The pH of the soil/septage mixture is to be maintained at 6.5 or greater at all times.
(d) The pH of the soil in the land disposal area is not to go below 6.5 as measured by annual soil tests.
(e) The annual cadmium (Cd) loading rate is not to exceed 0.5 kg/hectare/year. The following formula shall be used to calculate the annual cadmium loading rate:
Cd dry weight concentration (mg/kg) × whole application rate (metric tons/ha) × 0.001 (conversion factor) = Cd applied (kg/ha)
(1) Application of cadmium in excess of the annual loading rate shall be grounds for revocation of the land application license.
(f) The ceiling concentrations for the following substances shall be as follows (all values are milligrams per kilogram, dry weight basis):
Arsenic 41 Cadmium 39 Copper 1,500 Lead 300 Mercury 17 Nickel 420 Selenium 100 Zinc 2,800
(g) Sewage sludge testing. With respect to a licensee land applying sewage sludge, at least quarterly, testing of the sewage sludge in the holding tanks shall be conducted by an independent engineering or biosolids firm to ensure that the ceiling concentrations of the substances identified in section 64-42(f) are not exceeded. The results of this quarterly testing shall be provided to the county board of commissioners or its agent or designee. In no event may sewage sludge be land applied where any of the section 64-42(f) ceiling concentrations are exceeded. The applicant shall be responsible for the cost of all testing. In no event shall testing be performed less frequently than required under 40 CFR 503 regulations.
(h) Septage testing. With respect to a licensee land applying septage, at least once every six months during the first year of operation, and thereafter annually, testing of the septage shall be conducted by an independent engineering or biosolids firm to ensure that the ceiling concentrations of the substances identified in section 64-42(f) are not exceeded. The results of this annual testing shall be provided to the county board of commissioners or its agent or designee. In no event may septage be land applied where any of the section 64-42(f) ceiling concentrations are exceeded. The applicant shall be responsible for the cost of all testing. In no event shall testing be performed less frequently than required under 40 CFR 503 regulations.
(i) In no event shall sewage sludge and/or septage be land applied such that the cumulative pollutant loading rates and/or the pollutant concentrations limitations provided in 40 CFR 503.13, Tables 2 and 3, are exceeded.
Historia
(Ord. of 10-20-2003)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.