Construction of common access driveways shall conform to the following minimum standards.

Please see Figure 6 for a cross-section detail:

A. Easement width, 30 feet, 30 feet radius easement in cul-de-sac;

B. Roadbed width 20 feet;

C. Shoulder width, two feet;

D. Base width, 18 feet;

E. Pavement width, 16 feet;

F. Minimum radius at cul-de-sac transition and intersections, 20 feet;

G. Pavement type:

1. Plant mix, one inch thick over graded aggregate four inches thick (except

within the public right-of-way, which shall be six inches thick);

2. Concrete, four inches thick (except within the public right-of-way, which shall be six inches thick);

H. If a common access driveway terminates in a dead end, the termination shall be

either a cul-de-sac with a paved radius of 25 feet, or another termination method

that allows for vehicles to turn around safely and is acceptable to Hall County Engineering;

I. If a common access driveway is a cul-desac, the maximum length of the cul-de-sac shall be 1,000 feet;

J. Individual driveways joining the common driveway must be placed entirely on the

property that they serve;

K. Individual driveways joining the common driveway may only serve one lot;

L. Ditches: Front slope, maximum 2:1 ratio;

rear slope, maximum 2:1 ratio; 1 1/2 foot minimum depth;

M. Maximum finished driveway grade, 17 percent; driveway grades up to 20 percent may be approved by the county engineer

in extreme conditions;

N. Pavement crown, 1/4-inch per foot;

0. All slopes and shoulders to be grassed;

P. Minimum crossdrain pipe size, 18 inches;

Q. The driveway must intersect the public road at an angle of 65 degrees or greater;

R. The driveway must enter the public road at least 65 feet from any intersection of another common access driveway as measured from centerline to centerline. The driveway must enter the public road at

least 65 feet from another public road intersection as measured from the centerline of the common access driveway to the closest point of right-of-way intersection;

S. Intersection sight distance shall be as specified in the sight distance table in section 16.60.090 of this Code.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Res. of6-8-87, § 2; Code 1991, § 12.12.220; Res. of 11-22-00(1), § 2)