(a) Purpose. The intent of this program is to ensure compliance with the rules and regulations set forth in this division and to provide specific standards for FOG traps/interceptors location, type, size, construction, installation, and maintenance, to prevent excessive fats, oils, and grease from entering the Harris County sewer system.

Food service establishments shall provide means of preventing FOG discharges into the sanitary sewer system by installing and maintaining traps/ interceptors at the owner, leaseholder, or operator's expense using the guidelines set forth in this division. Failure to comply may result in penalties as set forth in section 7-82 of this division.

A list of the recommended ratings for commercial grease traps is presented in the table in section 7-79(g)(3) of this division. An alternative

to the proprietary grease trap is the pre-cast or poured in place concrete unit, usually located outside of the building.

(b) General requirements. The following design, administrative, operational, and other requirements are applicable to all food service establishments. Specific requirements for grease trap/interceptor construction for both new and

existing food service establishments can be found in section 7-79(g) of this division.

(1) All food service establishments shall have grease-handling systems approved by Harris County. Establishments whose greaseWATER, handling facilities are not in accordance

with this division shall install approved devices within 90 days from initial notification date.

(2) All food service establishment operations shall be subject to periodic review, evaluation, and inspection by Harris County.

(3) Violations of the FOG standards set forth in this division may result in enforcement actions as outlined in section 7-81 of this division.

(4) Food service establishments whose operations cause or allow excessive grease to discharge or accumulate in the sewer collection system may be liable for all cost associated to line blockages, line cleaning,

line repair where needed, any stop-ups or overflows, and any damage to public or private property that is a direct result of grease accumulation related to the facility in violation.

(5) All traps/interceptors shall be designed and installed in accordance with this division.

(6) All food service establishments must complete a permit application for the discharge of waste from food preparation and food service industries into the Harris County sewer system.

(7) The following class codes will be used as a classification system to categorize the food service facilities:

Class Codes Facility Classification A Restaurants/cafeterias B Institutions (schools, churches, etc.)

C Nightclubs/bar and grills D Deli stores/supermarkets E Other

(c) Inspection and sampling. Harris County may inspect the facility of any user to determine compliance with this division. Facilities where wastewater is created or discharged shall allow Harris County representatives ready access at all reasonable times to all parts of the premises for the purpose of inspection. Unreasonable delays and/or denial of access shall be in direct violation of this division, and be subject to the penalties as set forth in section 7-82 of this division.

The applicant for the installation of an approved device shall notify the Harris County Environmental Compliance Department before

any backfill, and when the device is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of a representative of Harris County.

(d) Trap/interceptor maintenance. Maintenance and clean-out schedules shall be provided at the request of Harris County. Harris County will evaluate the efficiency of the device during inspections, and may require an increase or decrease in the frequency of clean-outs.

(1) In-ground devices. Facilities with these devices shall adhere to a clean-out maintenance schedule as required by Harris County. Schedules will be set using the

following criteria: business operating hours, seating capacity, types of food service provided, size of device, and inspection results.

(2) Under-sink/compartmental devices. Facilities that are approved for these type of devices shall be required to:

a. Clean out on an as needed basis, minimum once every month.

b. Check devices at a minimum of once per week.

c. Maintain accurate records as defined in section 7-79(f) of this division.

(e) Wastehaulers. Wastehaulers must obtain a permit from Harris County. Wastehaulers will be issued a manifest to record clean-out information.

A list of permitted wastehaulers will be maintained by Harris County.

(1) Proper clean-out procedures. Proper cleanout procedures include, but are not limited to; total pump-out, dewatering, sludge/ solids removal, and water replacement.

Skimming is not an accepted method of cleaning out grease traps/interceptors.

(f) Records and records retention. Records of FOG removal systems shall be maintained on forms supplied by Harris County and available to Harris County upon request. Records shall be retained for a minimum of three years.

(g) Construction/sizing standards.

(1) Capacity. Traps should be sized for a minimum detention period of five minutes under peak flow conditions. Two options are shown below to size grease interceptors for restaurants and commercial kitchens. However, the minimum accepted size for a grease interceptor is 1,000 gallons.

Restaurants:

Size of Grease Interceptor = (ST)(20)(HR/12)(LF) in Gallons Where:

ST = Number of seats in dining area HR = Number of hours open LF = Loading factor

1.25 for interstates or freeways

1.0 other freeways

1.0 recreational areas

0.8 main highways

0.5 other highways Hospitals, nursing homes, other types of commercial kitchens with limited seating capacity:

Size of Grease Interceptor = (M)(ST)(5)(LF) in Gallons Where:

M = Number of meals per day ST = Number of seats in dining area LF = Loading factor

1.0 with dishwashing

0.5 without dishwashing

(2) General installation requirements.

a. Grease traps shall be installed as close to the source of grease as possible, or so installed to allow the wastestream to cool considerably before entering the trap system.

b. The grease trap shall either be baffled to retain congealed grease on the surface of the liquid or contain

two chambers for primary and secondary settling.

c. Influent shall enter the trap a minimum of six inches below the normal liquid level to keep the surface as

still as possible.

d. Effluent shall be drawn from near the bottom of the trap at a minimum of 18 inches below the liquid level.

e. Inlet and outlet of trap shall be provided with clean-outs for unplugging both sewers and dip pipes.

f. Food waste disposers may not be connected through a grease interceptor.

g. A large manhole, removable slab, or other cover to suit traffic load shall be installed so that all chambers of the trap are readily accessible for complete cleaning of both floatable and settleable solids.

h. Top or cover shall be gas tight.

i. Grease collected from an interceptor shall not be introduced into any drainage piping, public or private sewer.

j. Sanitary/domestic waste shall not be allowed to flow in any interceptor/ trap system.

k. All traps/interceptors shall have installed a means to prevent the introduction of materials into the pretreatment system such as paper, plastics, metals or other materials that which

if introduced into the sanitary sewer system or directly into the headworks of the POTW, will cause obstruction, interference or damage to any of the conveyance systems or POTW treatment works.

(3) New facilities. All food service establishments applying for water/sewer service shall be required to submit plans and/or

drawings outlining the plumbing layout and location of trap/interceptor installation.

Facilities will be evaluated using the following criteria to determine trap size:

a. Class code.

b. Hours of operation.

c. Seating capacity.

In-ground devices. Sizes shall be determined using the criteria listed above, and capacity standards as listed in section

7-79(g)(1) of this division.

Compartmental/under-sink devices. May be installed in instances where the type of food service presents little or no possibility of the discharge of fats, oils, and grease.

All devices must have approval prior to construction or installation by Harris County, and adhere to any local and/or state plumbing codes that apply.

(4) Existing facilities. All existing facilities upon notification, shall install an approved grease handling device within 90 days of such notification.

In situations in which in-ground devices are not feasible to install, facilities will be required to install an approved compartmental device. This variance must be approved by Harris County prior to installation.

When an existing facility's grease handling device is determined to be in noncompliance the responsible person(s) will be notified in writing, of the required

improvements which shall be made within 90 days of such notice.

(h) FOG enforcement. Harris County will conduct random inspections to insure that proper maintenance and clean-out schedules are being

followed.

Clean-out schedules will be set by Harris County using the variables as outlined in section 7-79(d) of this division. Clean-out frequency may increase or decrease depending on the efficiency (prevention of grease entering the sewer system) of the device installed. Failure to comply with these

schedules may subject the user/owner to the penalties as outlined in section 7-82 of this division.

Any facility that is found to be responsible for a sewer line blockage and/or sanitary sewer overflow will be liable for any expenses incurred from the cleanup or unstopping of the sewer line/

system.

(i) Detail shops/carwashes. Facilities that are required by the Board of Commissioners of Harris County to discharge their wastestream into the Harris County sanitary sewer shall meet the following requirements:

(1) An approved sand trap/interceptor must be installed and maintained for the prevention of sand, oil, and grease from entering the sewer system.

(2) Sand trap/interceptors shall be covered with an approved roof and devices in place to prevent storm water run-off from entering the sanitary sewer system.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 07-14, § 7, 12-16-2014)