Part II - CODE OF ORDINANCES / Chapter 18 - BUILDINGS AND BUILDING REGULATIONS / Article II - HIGH-EFFICIENCY PLUMBING FIXTURES

Sec. 18-30. Residential building construction.

Sobre este texto

  • As published by Municode, current through 2025-09-23
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) No plumbing fixture shall be installed which does not meet the standards listed in this section or the state minimum plumbing code, whichever is stricter. This includes all plumbing fixtures installed in newly constructed buildings or when replacing plumbing fixtures during remodeling or renovation of existing buildings, except as noted in section 8-32.

(b) The standards are as follows:

(1) A water closet or toilet that:

a. Is a dual flush water closet that meets the following standards:

1. The average flush volume of two reduced flushes and one full flush may not exceed 1.28 gallons;

2. The toilet meets the performance, testing, and labeling requirements prescribed by the following standards, as

applicable:

(i) American Society of Mechanical Engineers Standard Al 12.19.2-2008;

(ii) American Society of Mechanical Engineers Standard Al 12.19.14-2006 six-liter water closets equipped with a dual flushing device; and

3. Is listed to the WaterSense TM Tank-Type High Efficiency Toilet Specification; or

b. Is a single flush water closet, including gravity, pressure assisted, and electro-hydraulic tank types, that

meets the following standards:

1. The average flush volume may not exceed 1.28 gallons;

2. The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of

Mechanical Engineers Standard Al 12.192/CSA B45.1 or A112.19.14; and

3. The toilet must be listed to the WaterSense TM Tank-Type High Efficiency Toilet Specification;

(2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;

(3) A urinal and associated flush valve that:

a. Uses no more than 0.5 gallons of water per flush;

b. Meets the performance, testing, and labeling requirements prescribed by the American

Society of Mechanical Engineers Standard Al 12.19.2/

CSA B45.1;

c. For flushing urinals, meets all WaterSense TM specifications for flushing urinals; and

d. Where non-water urinals are employed, complies with American Society of Mechanical Engineers Standard Al 12.19.3/CSA B45.4 or American

Society of Mechanical Engineers Standard Al 12.19.19/CSA B45.4. Non-water urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where non-water urinals are installed

they shall have a water distribution line roughed-in to the urinal location at a minimum height of 56 inches (1 ,422 millimeters) to allow for the installation of an approved backflow prevention device in the event of a retrofit.

Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead

ends. Where non-water urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing;

(4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than 1.5 gallons of water per minute at a pressure of 60 pounds per square

inch in accordance with American Society of Mechanical Engineers Standard Al

12.18. I/CSA B. 125.1 and listed to the WaterSenseTM High-Efficiency Lavatory Faucet Specification; and

(5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more

than 2.0 gallons of water per minute.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 10-12-2021)