Where base flood elevation data are available:
(1) All manufactured homes placed or substantially improved on individual lots or parcels, in new or substantially improved manufactured home parks or subdivisions, in expansions to existing manufactured home parks or subdivisions, or on a site in an existing manufactured home park or subdivision where a manufactured home has incurred substantial damage as the result of a flood, must have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation.
(2) Manufactured homes placed or substantially improved in an existing manufactured home park or subdivision may be elevated so that either the lowest floor of the manufactured home is elevated no lower than one foot above the level of the base flood elevation or the manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade.
(3) All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.
(4) All recreational vehicles placed on sites must either:
a. Be on the site for fewer than 180 consecutive days;
b. Be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or
c. Meet all the requirements for new construction, including the anchoring and elevation requirements of this section.
Historia