(a) Glint and glare. Solar components must have a UL listing and must be designed with anti-reflective coating(s). All construction shall be in compliance with the National Electric Code and the Georgia Building Code. The developer shall graphically demonstrate to the zoning board through the use of renderings, photographs or similar credible media that proposed solar collection device or combination of devices shall be designed and located to avoid glare or reflection onto adjacent properties and adjacent roadways and shall not interfere with traffic or create a safety hazard. Screening, using fencing and/or vegetative buffers, shall be provided along all sides that do not collect energy to limit the visual impact of the site and minimize glare issues. Panels are to be located and situated so that glare does not create a distraction or nuisance to traffic or adjacent residential properties. An engineer or qualified consultant statement that glint and glare will not be offensive to residents and traffic must be submitted.

(b) Lot size. The minimum lot size required for a solar collection facility shall be ten acres. This excludes any proposed solar collection facility to be installed on an existing or proposed building.

(c) Setbacks. Solar panels and related equipment shall be subject to the following applicable setbacks and buffer requirements:

(1) With respect to adjacent rural zoning districts without a residential structure and adjacent commercial, office, and institutional zoning districts, a minimum setback of 100 feet from abutting boundaries.

(2) With respect to adjacent residential zoning districts and adjacent rural zoning districts with residential structures, a minimum setback of 300 feet from the closest residential structure.

(3) With respect to adjacent industrial zoning districts, a minimum setback of 100 feet from abutting boundaries.

(4) With respect to any state highway, a minimum setback from the right-of-way of 100 feet from abutting boundaries.

This excludes any proposed solar collection facility to be installed on existing or proposed building.

(d) Height limitations. No structure shall exceed a height greater than 25 feet, except for existing poles and overhead wiring. This is measured from finished grade at the base of the structure to its highest point. This would exclude any roof-mounted solar collection systems.

(e) Roof-mounted systems. Roof-mounted panels shall not extend beyond the perimeter of the building on which the system is mounted or constructed. The total height of the solar panels shall not exceed the maximum building height of the underlying zoning district.

Elevation drawings must be submitted to show:

(1) The highest finished slope of the solar collector and the slope of the finished roof surface on which it is mounted.

(2) The overall layout of the panels with the distance to the roof edge and any parapets on the building.

(f) Interconnection lines. All power lines from a ground-mounted solar energy system shall be located underground, excluding existing utilities.

(g) Noise level limitations. Inverter noise shall not exceed 40dBA at the property line.

(h) Controlled access. Access to the site must be controlled by a fence at least six feet in height, with emergency access allowed 24/7 to emergency/governmental authorities.

Mechanical equipment and inverter shall be controlled by:

(1) A fence at least six feet in height, topped with a three-strand barbed wire or razor wire; or

(2) A fence at least eight feet in height.

(i) Parking. The minimum number of parking spaces shall be one space for every two employees on shift of greatest employment, plus one space for every vehicle used for workrelated purposes.

(j) Airport. Solar panels shall not be placed in the vicinity of any airport in a manner that would interfere with airport flight patterns.

(k) [Other.] Other conditions that provide adequate protection for adjacent residential properties may be deemed reasonable and appropriate for the type of system, and may be added by the zoning board.

(l) Buffer requirements. Within all perimeter setbacks, 100 percent screening must be maintained to prevent visibility of the solar collection equipment and buildings. Any existing, natural undisturbed vegetative buffer must be left undisturbed. Where no vegetative screening exists, plantings of trees and other vegetative screening must be installed. Fencing with opaque screening and/or earthen berms may be used on the inside perimeter of the setbacks to comply with the complete visual screening of all structures. Any visual buffer must be established and maintained throughout the life of the project. Changes to the visual buffer plan may be approved by the planning and zoning board. Vegetative screening should be used as much as possible to screen structures at the entrance to the property.

(m) Lighting. To reduce light pollution, lighting of a ground-mounted SES shall:

(1) Be limited to the minimum reasonably necessary for its safe operation;

(2) Be directed downward where reasonably feasible;

(3) Incorporate full cut-off fixtures; and

(4) Reasonably utilize motion sensors.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 7-9-2013; Policy of 7-9-2024(2))

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:jefferson-county/code/20-1133@2024-07-09-52edee6285

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.