Part II - CODE OF ORDINANCES / Chapter 22 - MANUFACTURED HOMES
Sec. 22-5. Compliance to minimum health and safety standards.
Sobre este texto
- As published by Municode, current through 2020-08-20
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
All pre-owned manufactured homes shall comply with the following before being issued a certificate of occupancy by the building inspector:
(1) HUD code. Every pre-owned manufactured home located in the jurisdiction shall be in compliance with the Federal Manufactured Housing Construction and Safety Standards Act, 42 USC 5401—5445 (the HUD code) and shall not have been altered in such a way that the home no longer meets the HUD code.
(2) Interior condition. Every floor, interior wall, and ceiling of a pre-owned manufactured home shall be in sound condition. Doors and windows shall be operable, watertight and in good working condition. The floor system shall be in sound condition and free of warping, holes, water damage, or deterioration.
(3) Exterior condition. The exterior of all pre-owned manufactured homes shall be free of loose or rotting boards or timbers and any other conditions that might admit rain or moisture to the interior portions of the walls or to occupied spaces. The exterior siding shall be free of rot and rust. Roofs shall be structurally sound and have no obvious defects that might admit rain or cause moisture to collect on the interior portion of the home.
(4) Sanitary facilities. Every plumbing fixture, water, and waste pipe of a pre-owned manufactured home shall be in a sanitary working condition when properly connected, and shall be free from leaks and obstructions. Each home shall contain a kitchen sink. Each bathroom shall contain a lavatory and water closet. At least one bathroom shall contain a tub and/or shower facilities. Each of these fixtures shall be checked upon being connected to ensure they are in good working condition.
(5) Heating systems. Heating shall be safe and in working condition. Unvented heaters shall be prohibited.
(6) Electrical systems. Electrical systems (switches, receptacles, fixtures, etc.)
shall be properly installed and wired and shall be in working condition.
Distribution panels shall be in compliance with the approved listing, complete with required breakers, with all unused openings covered with solid covers approved and listed for that purpose. The home shall be subject to an electrical continuity test to ensure that all metallic parts are properly bounded.
(7) Hot water supply. Each home shall contain a water heater in safe and working condition.
(8) Egress windows. Each bedroom of a manufactured home shall have at least one operable window of sufficient size to allow egress if necessary.
(9) Ventilation. The kitchen in the home shall have at least one operating window or other ventilation device.
(10) Smoke detectors. Each pre-owned manufactured home shall contain one operable battery-powered smoke detector in each bedroom and in the kitchen, which must be installed in accordance with the manufacturer's recommendations.
(11) Entrances. All entrances (doors) must have steps with landings and hand rails within 30 days of power being turned on. Landings must be no less than three feet by three feet. The minimum width of any stair serving as a means of egress shall be a minimum of 36 inches. The width of the landing shall not be less that the width of stairways they serve. All steps and landing must have proper hand and guard railing where required. No loose block steps will be allowed.
(12) Skirting. To be installed within 30 days after the power inspection of the manufactured home. Clothes dryer exhaust vents and a/c condensation drain must extend through the skirting. A minimum of four ventilation openings are required. The minimum ventilation shall be 1/1,500 of the area of the crawl space.
(13) Floor zone requirements. Only for manufactured or mobile homes located in the flood zone:
a. Concrete footings. Pour concrete footings a minimum of 16 inches by 16 inches wide and six inches deep.
b. Piers. Piers must have mortar joints or sure wall (not stacked).
c. Height of home.
1. With base flood elevation. First floor at its finished level two feet above base flood elevation or anything that penetrates the finished floor two feet above based floor (example: HVAC duct work). Outside electrical equipment raised to first-floor level (HVAC unit). Certified surveyor has to determine the base flood elevations.
2. Without base flood elevation. First floor finished level three feet above highest point of the property where the manufactured or mobile home will be set-up. Elevation certificate must be provided by a surveyor.
Historia
(Ord. No. 2011-2, § 4, 3-17-2011)