(a) Purpose. The purpose of this program is to minimize the introduction of fats, oils, and greases into the county POTW. The main components of the program are the proper sizing, installation, and maintenance of grease interceptors. The administrative and inspection requirements of food service facilities are established herein as well.

(b) Definitions. Unless otherwise expressly stated or the context clearly indicates a different intention, the following terms shall, for the purpose of this document, have the meanings indicated in this section:

Domestic wastewater means wastewater from sanitary fixtures such as toilets and urinals.

Food service facility means any facility, which cuts, cooks, bakes, prepares, or serves food, or which disposes of food related wastes.

Garbage grinder means a device that shreds or grinds up solid or semisolid waste materials into smaller portions for discharge into the sanitary sewer.

Grease means a material composed primarily of fats, oil, and grease from animal or vegetable sources.

The terms fats, oil, and grease shall be deemed as grease by definition. Grease may also include petroleum-based products.

Grease enforcement coordinator means that employee designated by the county manager to oversee administrative enforcement of this article.

Hauler or transporter means one who transfers waste from the site of a user to an approved site for disposal or treatment. The hauler is responsible for assuring that all federal, state and local regulations are followed regarding waste transport.

Interceptor or separator or trap means a device so constructed as to separate, trap, and hold fats, oils, greases, sand, and grit substances from the wastewater discharged by a facility to prevent these substances from entering the sanitary sewer.

Under-sink or in-line grease trap means a device placed under or in close proximity to sinks or other facilities likely to discharge grease in an attempt to separate, trap or hold, oil and grease substances to prevent their entry into the sanitary sewer.

User means a source of discharge to the sanitary sewer of the county.

Waste or wastewater means the liquid and water-carried domestic or industrial wastes from dwellings, commercial establishments, industrial facilities, and institutions, whether treated or untreated, contributed to the sanitary sewer.

(c) General criteria:

(1) Installation requirements for new food service facilities. All proposed or newly remodeled food service facilities within the county wastewater service area shall be required to install an approved, properly operated and maintained grease interceptor. All interceptor units shall be installed outdoors of the food service facility building unless the user can demonstrate to the county that an outdoor interceptor would not be feasible. A passive interceptor inside the facility shall not be allowed. All interceptor units shall be of the type and capacity approved by the county. While under normal circumstances a 1,500 gallon outside grease interceptor will be required, under proper circumstances the grease enforcement officer may authorize the installation of a fully automated inside grease interceptor.

(2) Requirements for existing food service facilities. All existing food service facilities inside the county wastewater service area are expected to conduct their operations in such a manner that grease is captured on the user's premises and then properly disposed. This program will be handled in the following manner:

a. County will periodically inspect each food service facility on an as-needed basis to assure that each facility is complying with the intent of the program. The as needed inspection shall be determined by the county.

b. Each food service facility in the vicinity of any problem areas will be inspected. During such inspection, the county will review applicable maintenance records and will assess the adequacy of the facilities' grease control practices and grease control interceptor/ equipment.

c. Following the inspections, county will send written notice to the inspected food service facilities, containing a summary of the policy requirements, and the results of the inspection. The inspections will typically result in one of the following actions:

1. Facilities equipped with an appropriate and adequately sized grease interceptor which are meeting the intent of the county program through effective grease control practices will be commended for their compliance.

2. After notice and an opportunity to be heard, facilities not in compliance shall be required to develop and submit to county a proposed plan designed to achieve compliance through improved housekeeping and/or increased maintenance and periodic pumping of the existing grease interceptor/equipment.

3. Facilities found by the county to have failed to achieve compliance with the intent of the county program through improved housekeeping and increased maintenance and pumping of the existing grease interceptor/equipment will be required to install the necessary interceptor/equipment to bring the facility into compliance.

(3) Prohibited discharges. Domestic wastewater shall not be discharged to the grease interceptor unless specifically approved, in writing, by the county.

(4) Waste minimization plan. Food service facilities shall develop and implement a waste minimization plan pertaining to the disposal of grease, oils, and food particles.

(5) Floor drains. All floor drains located in the kitchen/food preparation area, or floor drains within any other area which have the potential to discharge grease, must be plumbed to an outside grease interceptor. Facilities with kitchen/food preparation areas lacking floor drains are required to provide a mop sink plumbed to drain through an approved under-sink or in-line grease trap.

(6) Location. Each grease interceptor shall be installed and connected so that it is at all times easily accessible for inspection, cleaning, and removal of the intercepted grease. Grease interceptors required under this article shall be installed outdoors of the food service facility. The best location is in an area outside of an exterior wall, but upstream from the domestic wastewater drain line. A grease interceptor may not be installed inside any part of a building unless approved in writing by county. The user bears the burden of demonstrating that an outdoor grease interceptor is not feasible.

(d) Design criteria:

(1) Construction of interceptors. Grease interceptors shall be constructed in accordance with the county plumbing standards and shall meet the minimum requirements of the adopted state and federal codes. Outdoor units shall have a minimum of two compartments with fittings designed for grease retention. All alternative grease removal devices or technologies shall be subject to the written approval of county. Such approval shall be based on demonstrated removal efficiencies of the proposed technology.

(2) Access. Outdoor grease interceptors shall be provided with two ductile iron manholes in accordance with ISO 1083. Covers shall be hinged and incorporate a 90-degree blocking system to prevent accidental closure. Covers shall be one man operable using standard tools and shall be capable of withstanding a test load of 120,000 lbs. Frames shall be circular with a 24 inches clear opening and shall incorporate a 360 degree, mechanically attached elastomer seating gasket for infiltration control and traffic shock. The hinged box shall include a self-cleaning, dual wiper infiltration plug. The frames depth shall not exceed four inches, and the flange shall incorporate bedding slots, bolt holes and lifting eyes. All components shall be black coated.

Frame weight: 73 lbs. Cover weight: 122 lbs. Total weight: 195 lbs. All grease interceptors shall be designed and installed to allow for complete access for inspection and maintenance of inner chamber as well as viewing and sampling of wastewater discharged to the sanitary sewer.

(3) Load-bearing capacity. In areas where additional weight loads may exist, the grease interceptor shall be designed to have adequate load-bearing capacity (example: vehicular traffic in parking or driving areas).

(4) Inlet and outlet piping. Wastewater discharging to the grease interceptor shall enter only through the inlet pipe of the interceptor. The inlet pipe bottom tee branch shall extend one foot below liquid level. The outlet pipe bottom tee branch shall be submerged to two-thirds of the liquid depth. Each grease interceptor shall have only one inlet and one outlet pipe.

(5) Sampling vault. After any interceptor a sampling vault for inspections on the effluent shall be installed. It should contain all the load bearing capacity as a trap. It shall contain one hinged manhole cover labeled SEWER.

(6) Interceptor sizing:

a. Outdoor grease interceptors shall not have a capacity of less than 1,500 gallons nor exceed a capacity of 3,000 gallons. No matter what the calculated capacity using the following formulas, the minimum interceptor size shall be 1,500 gallons. If the calculated capacity using one of the following formulas exceeds 3,000 gallons, then multiple units in series shall be installed. The size of a grease interceptor shall be approximated by the following methods and grease interceptor size shall be the larger of the two results.

(A) Interceptor Capacity (gallons) = (S) x (25) x (Hr/12) S= Number of Seats Hr= Maximum hours of daily operation (Include preparation & clean up)

(B) Interceptor Capacity (gallons)= (Sum of fixture flows) x (20) Type of Fixture Flow Rate (gpm) Restaurant hand sink 15 Pre-rinse sink 15 Single-compartment sink 20 Double-compartment sink 25 Two double-compartment sinks 35 Dishwasher up to 30 gallons 15 Dishwasher up to 50 gallons 25 Dishwasher up to 100 gallons 40 Other fixture Manufacturer peak

b. Under-sink or in-line grease interceptor requirements shall meet plumbing and drainage institute standard PDI-G101:

Type of Fixture Flow Rate (gpm) Grease Retention Capacity (lbs) Restaurant hand sink 15 30 Pre-rinse sink 15 30 Single-compartment sink 20 40 Type of Fixture Flow Rate (gpm) Grease Retention Capacity (lbs) Double-compartment sink 25 50 Two-double compartment sink 35 70 Dishwasher up to 30 gallons 15 30 Dishwasher up to 50 gallons 25 50 Dishwasher up to 100 gallons 40 80 Other Fixture Manufacturer peak gpm x 2 Grease interceptor designs represent minimum standards for normal usage. Installations with heavier usage require more stringent measures for which the user is responsible and shall pay the costs to provide additional measures if required by county. County reserves the right to evaluate interceptor sizing on an individual basis for facilities with special conditions, such as highly variable flows, high levels of grease discharge, or other unusual situations that are not adequately addressed by the formula.

(e) Grease interceptor maintenance:

(1) Pumping. All grease interceptors shall be maintained by the user at the user's expense. Maintenance shall include the complete removal of all contents, including floating materials, wastewater, and bottom sludges and solids. Decanting or discharging of removed waste back into the interceptor from which the waste was removed or any other grease interceptor, for the purpose of reducing the volume to be disposed, is strictly prohibited.

(2) Pumping frequency. Outdoor grease interceptors must be pumped out completely a minimum of once every three months. Under-sink or in-line grease interceptors must be pumped/cleaned out completely a minimum of once every month. Grease interceptors may need to be pumped more frequently as needed to prevent carry over of grease into the sanitary sewer collection system. In the discretion of the county, pumping frequency may be extended past the minimum period if user can demonstrate that such schedule meets with the intent of this article.

(3) Pump out order. When the oil and grease concentrations exceed county maximum discharge limits and/or the combined depth of bottom and top solids exceeds 33 percent of the total depth of the trap, county will issue a pump out order to the user. The user shall have seven days from receipt of the order to comply. Where an emergency exists, a written or verbal warning shall be given to the user, and the user will have 24 hours to comply.

(4) Disposal of interceptor pumped material. All waste removed from each grease interceptor shall be recorded on a proper manifest form. Also, all waste removed from each grease interceptor must be disposed at a facility approved by county to receive such waste in accordance with the provisions of this program. In no way shall the pumped material be returned to any private or public portion of the sanitary sewer collection system.

(5) Additives. Any additives placed into the grease interceptor or building discharge line system on a constant, regular, or scheduled basis shall be reported to county. Such additives shall include, but are not limited to commercially available bacteria or other additives designed to absorb, consume, or treat fats, oils, and grease. The use of additives shall in no way be considered as an alternative technology or a substitution for maintenance procedures required herein.

(6) Chemical treatment. Chemical treatments such as drain cleaners, enzymes, acids, and other chemicals designed to dissolve, purge, or remove grease shall not be allowed to enter the grease interceptor.

(f) Administrative requirements:

(1) Initial data acquisition. All food service facilities will be asked to complete a data sheet to establish the grease interceptor database. The county database will be updated with additional or modified information after each yearly inspection.

(2) Administrative fees. No fee will be charged for an annual inspection by county. However, if the user's grease interceptor is not in compliance with this section, a $50.00 re-inspection fee shall be charged for each inspection thereafter until compliance is achieved.

(3) Inspection and entry. Authorized personnel of the county, bearing proper credentials and identification, shall have the right to enter upon all properties subject to this program, at any time and without prior notification, for the purpose of inspection, observation, measurement, sampling, testing or record review, as part of this program.

(4) Record retention and reporting. All users must keep a record of any cleaning or maintenance of their grease interceptor. The following records must be kept on-site at the food service facility for a period of two years:

a. Manifests are required for all grease interceptors and shall contain the following information:

1. Food service facility (generator) information, including name, address, volume pumped, date and time of pumping, and generator signature verifying the information;

2. Transporter information, including company name, address, license plate number, permit number, driver name, and driver signature verifying transporter information;

3. Receiving information, including facility name, address, date and time of receiving, EPD permit number, and signature verifying receipt of the waste;

4. Manifests must be mailed, faxed, or electronically submitted to the grease enforcement coordinator within 14 days of interceptor maintenance; and

5. A manifest may not be required for under-sink or in-line grease interceptors if user can demonstrate to county a valid reason for such exception.

b. Maintenance logs are required for all under-sink and in-line interceptors. This log shall include the date, time, amount pumped or cleaned, hauler, disposal site, and signature. Log shall be kept in a conspicuous location for inspection. This log shall be made immediately available to the environmental health department and county representative upon request.

(g) Enforcement. The following list is arranged from least severe to most severe:

(1) Letter of warning (LW). When the county finds that a user is not in compliance with any provision of this article, the coordinator will serve that user with a written warning describing the noncompliance in detail.

(2) Notice of violation (NOV). If the noncompliance issue is not addressed by the user within a three-day period following the letter of warning, a written notice of violation will be issued.

According to the severity of the violation the user will be given up to 30 days from receipt of this notice to issue an explanation of the violation and a plan for the satisfactory correction and prevention thereof, to include specific required action, shall be submitted by the user to the county. Submission of this plan in no way relieves the user of liability for any violations occurring before or after receipt of notice of violation. Nothing in this section shall limit the authority of the county to take any action, including emergency actions or any other enforcement action, without first issuing a notice of violation.

(3) Site visit or re-inspection (SV). Upon the receipt of plans from the user and the allotted time for corrections to be made has expired, the county will re-inspect the facility to assure all violations have been corrected.

(4) Consent orders (CO). The county may enter into consent orders, assurances, of voluntary compliance, or other similar documents establishing an agreement with any user responsible for noncompliance. Such documents will include specific action to be taken by the user to correct the noncompliance within a time period specified by the document.

(5) Increased self-monitoring or reporting (ISM). The county may require monitoring devices to be installed at the facility in violation for measuring the amount of grease being released at said facility. Additional reporting of pumping frequency or other means of meeting the requirement in order to be in compliance will be required of the user.

(6) Cease and desist order (CDO). When the county determines that a user has violated, or continues to violate, any provision of this article, or any other standard or requirement, the county has the authority to issue an order to the user directing them to cease and desist all such violations and directing the user to:

a. Immediately comply with all requirements; and

b. Take such appropriate remedial or preventive action as may be needed to properly address a continuing or threatened violation, including halting operations and/or terminating the discharge.

(7) Judicial enforcement remedies or litigation (summons) (LIT). Should the county determine that a violation has jeopardized the health and/or welfare of the public or that a violation cannot be resolved with the user administratively, he may cause the issuance of a summons for violation of this article. A user who willfully or negligently violates any provision of this section, or order issued hereunder, shall, upon conviction, be guilty of a misdemeanor, punishable by a fine of not more than $1,000.00 per violation, per day, or imprisonment for not more than six months, or both.

(8) Remedies non-exclusive. The remedies provided for in this section are not exclusive. The county may take any, all or any combination of remedial actions against a non-compliant user."

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2019-03, § 1(14-207), 9-11-2019)

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:meriwether-county/code/36-106@2026-01-12-cdc90e1dbf

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Meriwether County Code of Ordinances, Sec. 36-106. Grease trap and waste receptor requirements | Georgia Commons