Sec. 18-90. Drawings and specifications.

Sobre este texto

  • As published by Municode, current through 2023-08-08
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Requirements. Two or more copies of specifications and of drawings drawn to scale with sufficient clarity and detail to indicate the nature and character of the work shall accompany the application for a permit.

(b) Additional data. The building official may require details, computations, stress diagrams, and other data necessary to describe the construction or installation and the basis of calculations. All drawings, specifications, and accompanying data required by the building official to be prepared by an architect or engineer shall be affixed with their official seal.

(c) Design professional.

(1) The design professional shall be an architect or engineer legally registered under the laws of the state regulating the practice of architecture or engineering and shall affix his official seal to said drawings, specifications, and accompanying data for the following:

a. All Group A buildings with occupancy over 500.

b. All Group F and H buildings with area over 10,000 square feet.

c. All Group E and I buildings.

d. Buildings and structures three stories or more in height.

(2) Exception: Single-family dwellings, regardless of size, shall require neither a registered architect or engineer nor a certification that an architect or engineer is not required.

(d) Structural and fire resistance integrity. Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistance wall, floor, or partition will be made for electrical, gas, mechanical, plumbing, signal, and communication conduits, pipes, and systems and also indicate in sufficient detail how the fire integrity will be maintained where required fire resistance floors intersect the exterior walls.

(e) Site drawings. Drawings shall show the location of the proposed building or structure and of every existing building or structure on the site or lot. The building official may require a boundary line survey prepared by a qualified surveyor.

(f) Hazardous occupancies. The building official may require the following:

(1) General site plan. A general site plan drawn at a legible scale which shall include, but not be limited to, the location of all buildings, exterior storage facilities, permanent accessways, evacuation routes, parking lots, internal roads, chemical loading areas, equipment cleaning areas, storm and sanitary sewer accesses, emergency equipment, and adjacent property uses.

The exterior storage areas shall be identified with the hazard classes and the maximum quantities per hazard class of hazardous materials stored.

(2) Building floor plan. A building floor plan drawn to a legible scale which shall include, but not be limited to, all hazardous materials storage facilities within the building and shall indicate rooms, doorways, corridors, exits, fire rated assemblies with their hourly rating, location of liquidtight rooms, and evacuation routes. Each hazardous materials storage facility shall be identified on the plan with the hazard classes and quantity range per hazard class or the hazardous materials stored.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2002-007, exh. A(4.2), 10-8-2002)