(a) Utility connections. All manufactured homes must be permanently connected to water, sewage, and electrical service.

(1) Water. Water service may be public or private. All water service must be freeze proof at elevations above and below the ground.

(2) Sewer. Installation of and/or connection to a new or existing on-site sewage systems must be permitted and/or final inspection completed by the Montgomery County Health Department.

(3) Electrical. Electrical service must meet minimum requirements for safety.

(b) Foundation. Unless placed on a permanent foundation, all manufactured homes must be installed in accordance with the Installation of Manufactured and Mobile Homes Rules and regulations established and published by the Georgia Safety Fire Commissioner (O.C.G.A.

§ 8-2-16 et seq.), installed with permanent skirting, secured with tie-down devices and provided with steps and landings. The installation of all required foundation requirements must be inspected and approved by the Building Official.

(c) Skirting. Installation of skirting shall be required. Installation shall be in accordance with the manufacturer's installation instructions. Acceptable materials include masonry, stone, fiberglass, simulated brick or stone, vinyl or other materials manufactured solely for the purpose of skirting.

(d) Tie-downs. Each manufactured home shall have tie-downs or other devices securing the stability of the manufactured home as per installation of Manufactured Homes and Mobile Homes Rules and Regulations established and published by Georgia Safety Fire Commissioner (O.C.G.A. § 8-2-160 et seq.).

(e) Steps and landings. Steps and landings are required for all homes at all exterior entrances/ exits. A minimum landing size of four feet by six feet of pressure treated lumber or elevated concrete is required. Wood landings are to be built on site, with posts placed 24 inches into soil for stability. Landings should be installed at the same elevation, but shall be no less than six inches below the elevation of the entrance/exit. Loose, stacked steps are strictly prohibited. If the landing is over 30 inches from the ground, sturdy handrails and guardrails are required.

(f) Recreational vehicles. Permanent connection of recreational vehicles to water, sewer, or electrical service is prohibited. Installation of recreational vehicles on piers and jacks permanently is also prohibited.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 8-2-2005(1), § 9)

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:montgomery-county/code/16-94@2026-11-23-eac1f6c8db

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Montgomery County Code of Ordinances, Sec. 16-94. Manufactured home installation requirements | Georgia Commons