(a) Foundation. The building foundation system shall be maintained in a safe manner and capable of supporting the load which normal use may cause to be placed thereon.

(b) Exterior walls. Every exterior wall shall be free of holes, breaks, loose or rotting boards or timbers, and any other conditions which might admit rain, or dampness to the interior portions of the walls or to the occupied spaces of the building. All siding material shall be kept in repair.

(c) Roofs. Roofs shall be structurally sound and maintained in a safe manner and have no defects which might admit rain or cause dampness in the walls or interior portion of the building.

(d) Means of egress. Every dwelling unit shall have safe, unobstructed means of egress with minimum ceiling height of seven feet leading to a safe and open space at ground level. Stairs shall have a minimum head room of six feet eight inches.

(e) Stairs, porches and appurtenances. Every inside and outside stair, porch and any appurtenance thereto shall be safe to use and capable of supporting the load that normal use may cause to be placed thereon and shall be kept in sound condition and good repair.

(f) Protective railings. Protective railings shall be required on any unenclosed structure over 30 inches from the ground level or on any steps containing four risers or more.

(g) Windows and doors. Every window, exterior door and basement or cellar door and hatchway shall be substantially weathertight, watertight and rodentproof; and shall be kept in sound working condition and good repair.

(h) Windows to be glazed. Every window sash shall be fully supplied with glass window panes or an approved substitute which are without open cracks or holes.

(i) Window sash. Window sash shall be properly fitted and weathertight within the window frame.

(j) Windows to be openable. It is considered desirable that every window required for light and ventilation for habitable rooms shall be capable of being easily opened and secured in position by window hardware.

(k) Hardware. Every exterior door shall be provided with proper hardware and be maintained in good condition.

(l) Door frames. Every exterior door shall fit reasonably well within its frame so as to substantially exclude rain and wind from entering the dwelling building.

(m) Protective treatment. All exterior wood surfaces, other than decay resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. All siding shall be weather resistant and watertight. All masonry joints shall be sufficiently tuck pointed to ensure water and air tightness.

(n) Accessory structures. Garages, storage buildings and other accessory structures shall be maintained and kept in good repair and sound structural condition.

(o) Interior floors, walls, and ceilings.

(1) Every floor, interior wall and ceiling shall be substantially rodentproof, shall be kept in sound condition and good repair and shall be safe to use and capable of supporting the load which normal use may cause to be placed thereon.

(2) Every toilet, bathroom and kitchen floor surface shall be constructed and maintained so as to be substantially impervious to water and so as to permit such floor to be easily kept in a clean and sanitary condition.

(p) Structural supports. Every structural element of the dwelling shall be maintained structurally sound and show no evidence of deterioration which would render it incapable of carrying normal loads.

(q) Protective railings and interior stairs. Interior stairs and stairwells more than four risers high shall have handrails located in accordance with the requirements of the building code. Handrails or protective railings shall be capable of bearing normally imposed leads and be maintained in good condition.

(r) Firestopping and draftstopping.

(1) Firestopping shall be maintained to cut off all concealed draft openings both horizontal and vertical and to form a fire barrier between floors and between the upper floor and the roof space.

(2) Draftstopping shall be maintained to cut off all concealed draft openings in floor/ceiling assemblies and in attics.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Code 2001, § 36-111(2)(D); Ord. of 1-20-1987)