Newton County · Código de ordenanzas
Part II - CODE OF ORDINANCES / Chapter 30 - HEALTH AND SANITATION / Article II - BODY CRAFT AND TATTOO REGULATIONS
Sec. 30-27. Body craft studio supplies.
Sobre este texto
- As published by Municode, current through 2023-04-18
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Single-use sterile articles shall be in uncompromised, sterilized condition at the time of their use, either by processing in a unit that meets the requirements for a sterilizer as defined herein, or packaged and sterilized by the manufacturer in an FDA-approved facility. These articles shall be handled in such fashion as to prevent their contamination including all requirements defined by this article and shall be stored in an area separate from chemical supplies and facilities utilizing open supplies of running water.
(b) Any jewelry used in any body crafting procedure shall consist of a material rated by the American Society for Testing Materials or the International Standards Organization as being suitable for permanent surgical implant, such as stainless steel, titanium, niobium, solid platinum or a dense low porosity plastic such as Tygon or PTFE. Copies of the jewelry manufacturer's documentation, which verify compliance with standards, must be available for inspection on request of the director. Solid 14 karat, or higher, white or yellow nickel-free gold may also be used. Purity verification must be available for inspection on request of the director.
(c) Only single-use sterile gauze shall be used.
(d) Single-use articles shall not be used on more than one client or customer for any reason, and must be disposed of after use as soon as possible without posing risk of contamination or exposure to the body crafter, the client, or the surrounding environment. The director shall determine and publish a list of instruments and articles that are considered single-use.
(e) Dyes and pigments shall be dispensed into single-use containers.
(f) After tattooing each individual, the remaining unused dye or pigment in the single-use container shall be discarded, along with the container, into a biohazard container.
Historia
(Ord. No. O-011706, § I(21-103(9)), 1-17-2006)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.