Ir al contenido
Georgia Commons
Menú

Oconee County · Código de ordenanzas

Part - CODE OF ORDINANCES / Chapter 22 - EMERGENCY SERVICES / Article III - FIRE PROTECTION AND PREVENTION / Division 5 - OTHER PROVISIONS

Sec. 22-132. Fire lanes and fire department access roads.

Sobre este texto

  • As published by Municode, current through 2026-04-07
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Designated fire lanes.

(1) Streets or drives adjacent to the following locations shall have designated fire lanes.

a. Any building 22,500 square feet or more with storage facilities, except for storage warehouse occupancies which are equal to or greater than 80 percent of the total building area and which comply with subsection (2) of the section.

b. Places of assembly with an occupant load of 300 or more.

c. The area five feet on each side of fire hydrants, fire department connections, and associated appliances or apertures used for fire protection.

d. All points of exit from nursing homes, hospitals, assisted living facilities, multi-family facilities, multi-storied office buildings and places of assembly.

(2) Minimum requirements for existing buildings. Every existing building shall be accessible to fire department apparatus by way of designated fire lanes and fire apparatus access roads as defined in the International Fire Code as adopted and amended by the Georgia Safety Fire Commissioner.

a. The fire marshal or the fire chief shall have the authority to require an increase in the minimum widths of fire lanes and fire apparatus access roads where they are inadequate for fire or rescue operations.

b. The creation, deletion, or modification of a fire lane shall be done in the fire marshal's best professional judgment in order to provide adequate fire and rescue operations.

(3) Minimum requirements for new construction. Fire lanes and fire apparatus access roads for new construction shall be developed in compliance with the currently adopted state minimum fire safety standards. Where designated fire lanes are required, they shall meet the following criteria:

a. The curbing shall be painted traffic yellow. Where curbing is not present, there shall be designated a twenty-foot wide, cross-hatched, traffic yellow way of access kept free of any obstructions.

b. Signs meeting the specifications described in the Manual of Uniform Traffic and Control Devices shall be spaced no less than 30 feet apart and legible from both directions of travel.

c. The distribution of fire hydrants along fire apparatus access roads shall be determined by reference to Appendices B and C of the currently adopted version of the International Fire Code.

d. During construction, when combustibles are brought onto the site in such quantities as deemed hazardous by the fire marshal, access roads and a suitable temporary supply of water acceptable to the fire chief shall be provided and maintained.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 6-5-2018(1), art. 5(§ 2))

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:oconee-county/code/22-132@2026-04-07-2c9fee4aa6

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Oconee County Code of Ordinances, Sec. 22-132. Fire lanes and fire department access roads | Georgia Commons