Paulding County · Código de ordenanzas
Part II - CODE OF ORDINANCES / Chapter 18 - BUILDINGS AND BUILDING REGULATIONS / Article II - TECHNICAL CODES
604.4.3.2. Landscape Irrigation System Required Components. All
Sobre este texto
- As published by Municode, current through 2025-12-09
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
new landscape irrigation systems shall include the following components:
1. A rain sensor shut-off installed in an area that is unobstructed by trees, roof over hangs, or anything else that might block rain from triggering the rain sensor shutoff.
2. A master shut-off valve for each controller installed as close as possible to the point of connection of the water but downstream of the backflow prevention assembly.
3. Pressure-regulating devices such as valve pressure regulators, sprinkler head pressure regulators, inline pressure regulators, WaterSense spray sprinkler bodies, or other devices shall be installed as needed to achieve the manufacturer's recommended pressure range at the emission devices for optimal performance.
4. Except for landscape irrigation systems serving a single-family home, all other systems must also include:
(a) A WaterSense irrigation controller; and
(b) At least one flow sensor, which must be installed at or near the supply point of the landscape irrigation system and shall interface with the control system, that when connected to the WaterSense controller will detect and report high flow conditions to such controller and automatically shut master valves. The flow sensor serves to aid in
detecting leaks or abnormal flow conditions by suspending irrigation. High flow conditions should be consistent with manufacturers' recommendations and specifications.
e. Chapter 9. Section 903.1 Roof Extensions. Insert: 6-inches
f. Chapter 13 NONPOTABLE WATER SYSTEMS, Section 1304 Reclaimed Water Systems. Add Section 1304.3.2 to read as follows:
1304.3.2 Connections to water supply. Reclaimed water provided from a reclaimed wastewater treatment system permitted by the Environmental Protection Division may be used to supply water closets, urinals, trap primers for floor drains and floor sinks, water features and other uses approved by the Authority Having Jurisdiction, in motels, hotels, apartment and condominium buildings, and commercial, industrial, and institutional buildings, where the individual guest or occupant does not have access to plumbing. Also, other systems that may use a lesser quality of water than potable water such as water chillers, carwashes or an industrial process may be supplied with reclaimed water provided from a reclaimed wastewater treatment facility permitted by the Environmental Protection Division. The use of reclaimed water sourced from any new private reclaimed wastewater treatment system for outdoor irrigation shall be limited to golf courses and agriculture operations as defined in the Official Code of Georgia Section 1-3-3, and such reclaimed water shall not be approved for use for irrigating any other outdoor landscape such as ground cover, tree, shrubs, or other plants. These limitations do not apply to reclaimed water sourced from existing private reclaimed water systems or from existing or new, governmentally-owned reclaimed wastewater treatment systems.
g. Appendix E, Section E101.1.2. Revise Section E.101.1.2 to read as follows:
Because of the variable conditions encountered in hydraulic design, it is impractical to specify definite and detailed rules for sizing of the water piping system. Accordingly, other sizing or design methods conforming to good engineering practice standards are acceptable alternatives to those presented herein. Without limiting the foregoing, such acceptable design methods may include for multi-family buildings the Peak Water Demand Calculator from the IAPMO/ANSI 2020 Water Efficiency and Sanitation Standard for the Built Environment, which accounts for the demands of water-conserving plumbing fixtures, fixture fittings, and appliances. If future versions of the Peak Water Demand Calculator including other building types, such as commercial, such updated version shall be an acceptable design method.
(3) International Residential Code.
i. Revise Table 301.2(1) in Chapter 3 by adding the following information to the blank spaces:
a. Ground snow load (lbs. Per square foot) — 5.
b. Wind speed (fastest mile) — 90.
c. Seismic design category — B.
d. Weathering — moderate.
e. Frost line depth — 12" minimum.
f. Termite damage — very heavy.
g. Winter design temp. for heating facilities — 22°F.
h. Ice Barrier Underlayment Required — No.
i. Flood Hazards — Yes.
j. Air Freezing Index — 225.
k. Mean Annual Temperature — 55 F to 60 F.
ii. The following section is hereby included by reference:
a. Section 105.2 Work exempt from permit.
(4) International Property Maintenance Code.
i. The following sections are hereby revised:
a. Section 101.1. Insert: Paulding County
b. Section 103. Change title to "Enforcement Responsibility"
c. Section 103.1 through 103.3. Remove in its entirety
d. Section 103.5. Remove in its entirety
e. Section 106.4. Remove in its entirety and replace as follows: "106.4 Violation penalties. Any person who shall violate a provision of this code, or fail to comply therewith, or with any of the requirements thereof, may be subject to a fine of not less than $100.00 and not more than $500.00 and 60 days in jail or both. Each day that a violation continues after due notice has been served shall be deemed a separate offense."
f. Section 111.1. Replace in its entirety and replace as follows: "111.1 Application for appeal. The appeal process shall be performed by the existing county board of adjustments and appeals as outlined in sections 18-121 through 18-133.
g. Sections 111.2 through 111.8. Remove in its entirety
h. Section 302.4. Insert: 24-inches
i. Section 304.14. Insert: May 15 to October 15
j. Section 602.3. Insert: October 1 to May 1
k. Section 602.4. Insert: October 1 to May 1
(5) International Existing Building Code.
i. The following section is hereby revised:
a. Section 101.1. Insert: Paulding County
b. Section 103. Remove in its entirety
c. Section 105.3. Replace "the Department of Building Safety" with "Paulding County"
d. Section 108. Remove in its entirety
e. Section 105.1.1 and 105.1.2. Remove in its entirety
f. Sections 106 through 111. Remove in its entirety
g. Section 112.1. Replace in its entirety and replace as follows: "112.1 Application for appeal. The appeal process shall be performed by the existing county board of adjustments and appeals as outlined in sections 18-121 through 18-133.
h. Sections 113 through 117. Remove in its entirety
i. Section 1301.2. Insert: 1988
(e) For all permits granted or approved by Paulding County under earlier versions of any or all of these codes, it is hereby declared to be the intention of the county to enforce the version of the code which was in effect when the project was approved.
(Res. No. 99-14, 2-9-1999; Res. No. 04-15, § 1, 4-29-2004; Res. No. 07-05, § 1, 2-27-2007; Res.
No. 10-25, § 1, 12-14-2010; Ord. No. 19-03, § 1, 7-23-2019; Ord. No. 24-01, § 1, 1-23-2024)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.