(a) An ultrasonic cleaning unit and operational medical-grade autoclave (Class B) shall be provided in each body art studio.
(b) Ultrasonic cleaning units shall be clearly labeled �biohazardous� and shall be operated in accordance with the manufacturer's recommendation.
(c) The ultrasonic cleaning unit and medical grade autoclave shall be used and maintained according to manufacturer's specifications. Each ultrasonic cleaning unit and medical-grade autoclave shall be emptied and thoroughly cleaned and disinfected per manufacturer's recommendations. Ultrasonic cleaning unit and autoclave maintenance records must be maintained for two years and be made available upon request.
(d) Used non-disposable instruments shall be kept in a separate labeled, punctureresistant container until cleaned. The cleaning method shall include the following:
(1) Instruments should be pre-scrubbed prior to being placed into an ultrasonic cleaning unit.
(2) After removal from the ultrasonic cleaning unit, instruments should then be brush scrubbed in hot water and soap, then rinsed in clean water.
(3) Prior to being placed in the autoclave all equipment shall be bagged, labeled as to contents, initialed, dated and sealed. If multiple autoclaves are in use, the autoclave used must be designated on the packaging.
(4) Instruments shall then be packed individually in sterilized packs and sterilized in a medical-grade autoclave. All sterilized packs shall contain either a sterilized indicator or internal temperature indicator.
(5) Each autoclave bag must be used in accordance with the manufacturer's recommendations and may hold no more than one individual item (ex. one tube or needle bar). A piercing set may be bagged together.
(e) After sterilization, the packaged instruments shall be stored in a clean dry cabinet or other tightly covered container reserved and labeled for storage of sterile instruments.
(f) If a sterilized package has been breached or allowed to get wet, the instrument(s) must be re-packaged and sterilized again before use.
(g) A log of sterilization procedures shall be maintained near the sterilizing equipment.
Included in the log shall be type of load, quantity of load, temperature, pressure and length of sterilizing time.
(h) Spore indicators shall be used a minimum of at least once a month unless the manufacturer specifies more frequent monitoring or after 40 hours of usage, whichever comes first, and the results must be kept on-site for a minimum of two years. An independent commercial testing laboratory contracted by the operator/ body artist or both shall perform monthly biological spore testing of the autoclave. A provision shall be included in the contract between the operator or body artist (or both) with the commercial testing laboratory requiring the commercial testing facility to notify the Peach County Health Authority of any failure of the autoclave to eradicate all living organisms, including spores.
(i) Upon notification of a positive microbiological monitoring report, the sterilizer shall be immediately checked for proper use and function and the operator shall cease use of the sterilizer immediately upon receipt of the positive report. Any items remaining bagged after sterilization must be reprocessed and sterilized by an autoclave approved for use prior to return to service. Three consecutive negative biological tests must be achieved before the studio is reopened. The studio shall have the option to obtain a properly functioning sterilizer with a negative biological report in order to remain open or if the studio has more than one autoclave in operation they may be given approval to remain open. The health authority will consider the body art studio's emergency plan should autoclave failure or malfunction occur.
(j) Any item or instrument used for body art that is contaminated during the procedure shall be discarded and replaced immediately with a new disposable item or a new sterilized instrument or item before the procedure resumes.
Historia
(Ord. No. 09-13-2016(1), § X, 9-13-2016)