Ir al contenido
Georgia Commons
Menú

Seminole County · Código de ordenanzas

Part II - CODE OF ORDINANCES / Chapter 26 - ENVIRONMENT / Article III - GROUNDWATER RECHARGE AREA PROTECTION

Sec. 26-74. Criteria.

Sobre este texto

  • As published by Municode, current through 2011-03-15
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

The following criteria shall apply in significant recharge areas:

(1) The county shall not issue any permits for new sanitary landfills not having synthetic liners and leachate collection systems.

(2) The county shall not issue any new permits for the land disposal of hazardous wastes.

(3) The county shall require all new facilities permitted or to be permitted to treat, store, or dispose of hazardous waste to perform such operations on an impermeable pad having a spill and leak collection system.

(4) New aboveground chemical or petroleum storage tanks, having a minimum volume of 660 gallons, shall have secondary containment for 110 percent of the volume of such tanks or 110 percent of the volume of the largest tank in a cluster of tanks. (Note:

These figures are consistent with US EPA rules for oil pollution prevention, 40 CFR 112.1.) Such tanks used for agricultural purposes are exempt, provided they comply with all federal requirements.

(5) New agricultural waste impoundment sites shall be lined if they are within:

a. A high pollution susceptibility area.

b. A medium pollution susceptibility area and exceed 15 acre-feet.

c. A low pollution susceptibility area and exceed 50 acre-feet.

As a minimum, the liner shall be constructed of compacted clay having a thickness of one-foot and a vertical hydraulic conductivity of less than five by ten7 cm/sec or other criteria established by the natural resources conservation service.

(6) All residential lots not served by a public water system and public sewage system shall be at least one and one-half acres in size (consult the county health department) or the following size limitations, whichever is larger. New homes served by a septic tank/ drainfield system shall be on lots having minimum size limitations as follows, based on application of table MT-1 of the department of human resources manual (hereinafter DHR table MT-1). The minimums set forth in table MT-1 may be increased further based on consideration of other factors (set forth in sections A—F) of the DHR manual.

a. If lots are within a high pollution susceptibility area, 150 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1.

b. If lots are within a medium pollution susceptibility area, 125 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1.

c. If lots are within a low pollution susceptibility area, 110 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1.

(7) New mobile home parks served by septic tank/drainfield systems shall have lots or spaces having minimum size limitations as follows, based on application of table MT-2 the department of human resources' manual for on-site sewage management systems (hereinafter DHR table MT-2). The minimums set forth in table MT-2 may be increased further based on consideration of other factors (set forth in sections a—f) of the DHR manual.

a. If lots or spaces are within a high pollution susceptibility area, 150 percent of the subdivision minimum lot or space size of DHR table MT-2.

b. If lots or spaces are within a medium pollution susceptibility area, 125 percent of the subdivision minimum lot or space size of DHR table MT-2.

c. If lots or spaces are within a low pollution susceptibility area, 110 percent of the subdivision minimum lot or space size of DHR table MT-2.

(8) No construction may proceed on a building or mobile home to be served by a septic tank unless the county health department first approves the proposed septic tank installation as meeting the requirements of the DHR manual and subsections (6) and (7) of this section.

(9) Lots of record approved prior to the adoption of the ordinance from which this article is derived are exempt from the requirements of subsections (6) and (7) of this section.

(10) New facilities that handle hazardous materials of the types listed in section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage tanks) and in amounts of 10,000 pounds or more on any one day, shall perform their operations on impervious surfaces and in conformance with any applicable federal spill prevention requirements and local fire code requirements.

(11) The department of natural resources shall require conservative design in any new permits for the spray irrigation of wastewaters or the land spreading of wastewater sludge in areas having high pollution susceptibility. This shall be accomplished by comparing the department's criteria for slow rate land treatment (February 1986 or latest edition) with amendments and other technical publications to site-specific information submitted by a registered professional engineer for each project.

(12) Permanent stormwater infiltration basins shall not be constructed in areas having high pollution susceptibility.

(13) Exclusive of mining settling basins, new wastewater treatment basins shall have an impermeable liner in areas having high pollution susceptibility.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 8-14-2001(2), § 4)