Ir al contenido
Georgia Commons
Menú

Tattnall County · Código de ordenanzas

Part II - CODE OF ORDINANCES / Chapter 34 - HEALTH AND SANITATION / Article V - ON-SITE SEWAGE MANAGEMENT

Sec. 34-107. Minimum lot sizing for on-site sewage management.

Sobre este texto

  • As published by Municode, current through 2025-04-07
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Minimum lot size requirements for these lots utilizing on-site management systems are as follows for single family dwellings including but not limited to:

manufactured or mobile homes, stick built homes, modular homes, etc., and individual lots in subdivisions or mobile home lots located in areas other than commercial mobile home parks. Area requirements for multiple dwellings on a single recorded lot, where not prohibited by local zoning, must be provided in multiples of the following minimum lot sizes for each dwelling to be constructed on the recorded lot. See table MT-1 as follows. These minimum lot size requirements in this table may be increased further based on consideration of other factors and requirements upon application of the state department of human resources manual for on-site sewage management (DHR Manual), including those currently set forth in sections A—F of the DHR manual.

TABLE MT-1

Minimum (Min.) Lot Sizes, Minimum Lot Widths and Maximum (Max.) Allowable Sewage Flow for the Type of Water Supply System.

Type of Water Supply System Non-Public* (Individual) Public Min. lot size 43,560 square feet 21,780 square feet Min. lot width 150 ft. 100 ft.

Max. sewage flow 600 gpad** 1200 gpad *In this context "nonpublic" means an individual water supply system or any other water supply system which is not a "public" water supply system.

**gpad = gallons per acre per day = gal/acre/day.

(b) Minimum lot sizing requirements for those lots utilizing on-site sewage management systems are as follows in table MT-2 for multi-family residential dwellings, all other non-single family dwellings and commercial structures, and this also includes mobile home parks. These minimum lot size requirements in this table may be increased further based on consideration of other factors and requirements upon application of the state department of human resources manual for on-site sewage management (DHR manual), including those currently set forth in sections A—F of the DHR manual.

TABLE MT-2

Minimum (Min.) Lot Sizes, Minimum Lot Widths and Maximum (Max.) Allowable Sewage Flow for the Type of Water Supply System.

Type of Water Supply System Non-Public* (Individual) Public Min. lot size 43,560 square feet 21,780 square feet Min. lot width 150 ft. 100 ft.

Max. sewage flow 600 gpad** 1200 gpad *In this context "nonpublic" means an individual water supply system or any other water supply system which is not a "public" water supply system.

**gpad = gallons per acre per day = gal/acre/day.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 9-10-2001, app. 1)

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:tattnall-county/code/34-107@2025-04-07-00291fc9d6

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Tattnall County Code of Ordinances, Sec. 34-107. Minimum lot sizing for on-site sewage management | Georgia Commons