Sec. 28-199. Combined waste stream formula.
Sobre este texto
- As published by Municode, current through 2026-07-09
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Where process effluent is mixed prior to treatment with wastewaters other than those generated by the regulated process, fixed alternative discharge limits may be derived by the Authority, or by the industrial user with the consent of the Authority. The alternative limits shall be applied to the mixed effluent. When deriving alternative categorical limits, the Authority or industrial user shall calculate both an alternative daily maximum value using the maximum value(s) specified in the appropriate categorical pretreatment standard(s) and an alternative consecutive sampling day average value using the monthly average value(s) specified in the appropriate categorical pretreatment standard(s). The industrial user shall comply with the alternative daily maximum and monthly average limits fixed by the Authority until the Authority modifies the limits or approves an industrial user's modification request. Modification is authorized whenever there is a material or significant change in the values used in the calculation to fix alternative limits for the regulated pollutant. An industrial user must immediately report any such material or significant change to the Authority.
(1) Alternative limit calculation. Alternative limits shall be calculated using the formula and instructions in 40 CFR 403.6(e).
(2) Alternative limits below detection limit. An alternative pretreatment limit may not be used if the alternative limit is below the analytical detection limit of any regulated pollutants.
(3) Choice of monitoring location. Where a regulated process waste stream is combined prior to treatment with wastewaters other than those generated by the regulated process, the industrial user may monitor either the segregated process waste stream or the combined waste stream for the purpose of determining compliance with the applicable pretreatment standards. If the industrial user chooses to monitor the segregated process waste stream, it shall apply the applicable categorical pretreatment standard. If the user chooses to monitor the combined waste stream, it shall apply the alternative discharge limit calculated using the combined waste stream formula as described in this section. The industrial user may change monitoring locations only after receiving prior approval from the Authority. The industrial user may not use dilution as a substitute for adequate treatment to achieve compliance with applicable standards.
Historia
(Ord. No. O-03-22, Exh. A, 11-10-2022)