PRINCIPAL BUILDING SETBACKS (feet)

DISTRICT

Units Per Acre

EXTERIOR

PERIMETER

BUFFER PER

DEVELOPMENT

FRONT,

ARTERIAL OR

COLLECTOR

STREETS

FRONT,

OTHER

STREETS SIDE REAR

R-I 35 25 15 25

R-II 35 25 15 25

R-III 35 25 15 25

R-IV 40 25 15 25

MHP ** ** ** **

NS 20 35 (A) 20 15 (A) 20 (A)

HB 20 35 (B) 20 15 (B) 20 (B)

CB 20 35 (A) 20 15 (A) 20 (A)

CBD 20 10 (B) 10 5 (B) 20 (B)

O-P 20 35 (A) 20 15 (A) 20 (A)

M-I 20 35 (B) 20 15 (B) 20 (B)

M-II 30 35 (C) 20 15 (C) 20 (C)

A 100 80 25 35

PDD 35 45 18 12* 18*

** See Article XI, Section 1103 and 1104.

Measurements for all setbacks are taken beginning from the end of the right-of-way.

NOTE: Additional setbacks may be required for specified uses as provided in permitted uses sections of particular zoning districts or as to special uses granted by permit.

(A) When development in this district abuts an A, R-I, R-II, or R-IV zoning district boundary, a vegetative buffer with a minimum width of five (5) feet and six (6) feet in height shall be provided along the entire property line abutting said zoning district.

(B) When development in this district abuts an A, R-I, R-II, or R-IV zoning district boundary, a vegetative buffer with a minimum width of five (5) feet and six (6) feet in height shall be provided along the entire property line abutting said district. A five

(5) foot vegetative wide buffer shall be required when this district abuts an R-3, MHP or O-P zoning district.

(C) When development within this district abuts an A, R-I, R-II or R-IV zoning district boundary, a vegetative buffer with a minimum width of twenty-five (25) feet shall be provide along the entire property line abutting said zoning district. A twenty (20) foot wide vegetative buffer shall be required when this district abuts an R-3, MHP or O-P zoning district.

How many square feet in an acre?

There are 43,560 square feet in one acre.

To determine the acreage size of your lot, divide the total square footage by 43,560.

For example, a lot is 110 feet wide by 115 deep.

• 110 x 115 = 12,650 square feet

• 12,650 ÷ 43,560 = 0.29 acre If you have 110.25 acres:

• 110.25 x 43,560 = 4,802, 490 square feet

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:alto/zoning/2201@2025-08-25-527a9862c9

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Alto Zoning Ordinance, Section 2201. Minimum setback and buffer requirements by zoning district | Georgia Commons