Avondale Estates · Ordenanza de zonificación
Appendix A / Chapter 21 - ZONING ORDINANCE / Article 6 - SITE DEVELOPMENT FEATURES / Division 6.1 - GENERAL LOT AND BUILDING REGULATIONS
Sec. 21-6.1.2. Building height.
Sobre este texto
- As published by Municode, current through 2024-04-17
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
A. Building height is regulated by zoning district in section 21-2.1.3 and section 21-2.2.3 - dimensional standards for residential and commercial districts and table 21-3.2.9 - fa9ade types for the central business district.
B. Exceptions.
l. Farm buildings and farm-related structures are not subject to building height limits when located on bona fide farms.
2. Belfries, clock towers, cupolas, domes, flag poles and spires may exceed maximum building limits, provided they are not intended for human occupancy.
3. Bulkheads, elevator and equipment penthouses, chimneys, water tanks and similar structures may exceed maximum height limits, provided they do not cover more than twenty-five (25) percent of the total roof area of the building on which they are located.
4. Telecommunications towers and antennas are subject to their own special height limits (see division 5.8 - wireless communications).
5. Building-mounted solar energy systems shall not extend more than three (3) feet above the roof line (see also section 21-5.9.14 - solar energy systems) and shall comply with maximum building height.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.