Avondale Estates · Ordenanza de zonificación
Appendix A / Chapter 21 - ZONING ORDINANCE / Article 6 - SITE DEVELOPMENT FEATURES / Division 6.1 - GENERAL LOT AND BUILDING REGULATIONS
Sec. 21-6.1.3. Building design standards.
Sobre este texto
- As published by Municode, current through 2024-04-17
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
A. Intent. These criteria are intended to address a building's appearance and integration into commercial districts. The criteria are intended to elicit high quality materials, enhanced pedestrian experience, an appropriate scale, and a development pattern that effectively implements the city's planning and visioning documents.
B. Applicability. The building design regulations of this section apply to all buildings in the 0-I and GC Districts, unless otherwise expressly stated.
1. Applicable {a<;ades. The building design standards apply to all fai;ades visible from the street, facing streets, facing main parking lots, and adjacent to or visible from required open spaces, unless otherwise noted.
C. Exterior finish materials:
1. Primary building materials shall be used on at least seventy (70) percent of any building fai;ade,
2. Secondary building materials may be used on up to thirty (30) percent of any exterior building fai;ade, calculated on the basis of each individual fai;ade.
3. Building materials, other than those expressly identified in this Section, may be used on up to ten (10) percent of any exterior building fai;ade, provided they have not been prohibited by this section .
4. Material proportion calculations shall not include building foundations, window systems, and doors. Proportions are calculated on the basis of each individual fai;ade.
5. Materials shall continue around the corner of the building onto fai;ades not visible from the public street a minimum depth of one (1) architectural bay.
6. Prohibited materials. Synthetic stucco, concrete masonry units (CMU), and vinyl are not permitted as exterior finish materials.
7. Building fai;ades shall be constructed ofno more than three (3) primary materials and/or colors.
Additional materials may be used as secondary, trim, or accent materials.
8. Awnings. Plastic and vinyl awnings are prohibited. Materials repurposed into textiles for use on an awning is permitted.
9. Exterior wall finish materials are required, as follows:
a. Primary: Brick, including full-depth and half-depth masonry brick; stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone;
and unpainted terracotta.
b. Secondary: Metal panels and siding; wood, including natural wood or cement-based artificial wood siding.
D. Building articulation.
1. In order to avoid large expanses of flat (one-dimensional) exterior walls along sidewalks, building fa,;ades over fifty (50) feet in length along a street, including abutting attached houses, shall incorporate wall projections or recesses a minimum of twelve (12) inches in depth. The combined length of such recesses and projections shall constitute at least twenty (20) percent of the total fa,;ade length along the public street.
2. One (1) of the following articulations is required to divide the fa,;ade into vertical divisions at increments no greater than one hundred (100) feet, as measured along the base of the fa,;ade :
a. A change of fa,;ade material and window system from grade to roof; or
b. Change of building height of at least one (1) story; or
c. A change in fa,;ade composition and/or architectural style from grade to roof; or
d. An open space or pedestrian passage with a minimum width of fifteen (15) feet and a minimum depth of thirty (30) feet.
e. Similar means intended to convey the impression of separate buildings.
f. Change in color alone, window system alone, or setback alone, may not be used to satisfy this requirement.
3. Building roof lines along street-facing fa,;ades shall change at least once every two hundred
(200) feet of fa,;ade length. This change shall occur for a minimum length of twenty (20) feet and be accomplished through at least one (1) of the following:
a. A change of roof parapet wall height and material;
b. A change of roof cornice design;
c. A change in the number of stories;
d. A change in roof-shape.
E. Blank walls. Blank wall area applies to ground and upper story fa,;ades visible from a street (not including an alley) or open space.
1. There shall be no more than twenty (20) feet of blank wall area.
2. Blank wall area can be broken up or interrupted to meet these provisions with any one (1) of the following interventions:
a. Fenestration; or
b. Substantial material change. Paint color alone does not constitute a material change; or
c. Fa,;ade articulation greater than twelve (12) inches in depth; or
d. Patterns and designs articulated with building materials.
e. Vertical green walls.
f. Signage and murals as permitted in chapter 5 - sign regulations.
3. Blank wall area is measured in linear feet applied in both vertical and horizontal directions.
See figure 21-6.1.3.E blank wall area.
L ~ . ·r·.---i--- -- -·- - - --.-~ 1--~;.i--:- -:_-_-·_·_-_---,+-rr· __ ·_·_--. _ _ -_··-_·-_····_··-_---_·_·-_•-_··-_-1·.,,--c·1_-·-_·~r J- .. I .. H ' t.
~ I l I r -· ~ Ji -~===1 . j, "·- · ,, !bl nk,. J!: ['.T' .. ,, - ,.. i_ ~ll _ _ rea l., : · ~.-r j ;
1 ! k I ------, ea i 8- .............. --~ -· ~ta~ n a,rarea Figure 21-6.1.3.E Blank Wall Area
F. Residential balconies.
1. Where balconies are incorporated into building design, they shall be integral to the far;ade .
2. Balconies on stepped-back stories may be independently secured, extending from the far;ade as a cantilever.
3. Juliet balconies are prohibited.
G. Window systems.
1.
2.
3.
4.
Fai;ades on commercial and MF -zoned lots shall provide a minimum ground floor fenestration of forty (40) percent on the ground story and twenty-five (25) percent on upper stories.
Fenestration is the minimum percentage of window and door glass that must cover a fai;ade, It is calculated based fai;ade area and by floor. The fac;ade area used to determine fenestration is measured from the top of the finished door to the top of the finished floor above or top of a roof parapet.
Fenestration requirements apply to fai;ades that abut a public or private street (not including an alley), or a required open space.
Glass used to satisfy fenestration requirements shall be unpainted, shall have a transparency (visible light transmission)
higher than seventy (70) percent and shall have an external reflectance of less than fifteen (15) percent. Transparency and external light reflectance shall be established using the manufacturer's specifications.
",, Level 3 FFE , 8 ii'.
g ~ I .. Level 2 FFE __ LJJLJJ Upper Story Fenestration -·---·-··--· - ______ ,, __ _ 'LJ[ []~± -~:;.~,;,~~ Ground Floor
- - Fenestration .,,_LevE!_l_1 FFE - - _-_-_-_-_-_-_-_-_-_-_-_-_-_:_-_:_-_-_-_-_-_-_-_-_-_ Figure 21-6.1.3.G Fenestration Calculation Area
5. Window frames, sashes, mullions, and similar features that are integral to the window system count towards fenestration requirements. Opaque doors and windows do not.
6. No shades, blinds, or other coverings are permitted on the ground floor fenestration of any non-residential building.
7. Grilles, inoperable shutters, and other faux window treatments are prohibited.
8. Window systems shall be recessed from the fai;ade of the building a minimum of three (3) inches. This reveal shall be accomplished through the design of the window casing reveals and frames.
H. Pedestrian access. The pedestrian access regulations of section 21-6.2.13 - pedestrian access and circulation apply.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.