Burke County · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 26 - LAND DEVELOPMENT CODE / Article IV - SITE DESIGN STANDARDS
26-4.02.01. Design standards for lots.
Sobre este texto
- As published by Municode, current through 2025-10-14
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Only one principal detached single-family residential building and its allowable accessory buildings shall hereafter be erected on any one lot, parcel, or tract of land in any rural zoning district or single-family residential zoning district.
(b) No more than one single-family residence may be served by a septic tank.
(c) Except as specifically provided in the LDC, no lot existing at the time of adoption of the LDC shall be reduced, divided, or changed so as to produce a lot or tract of land which does not comply with the minimum dimensional or area requirements of this section.
(d) Where the owner of a lot of record at the time of the adoption of the LDC, or their successor in title thereto, does not own sufficient land to enable him or her to conform to the lot dimensional or area requirements of the LDC, shall be allowed to build upon said lot in accordance with all other regulations of the applicable zoning district and with the approval of the board of health when such lots utilize a septic tank waste water system.
(e) Land which is required, dedicated, and accepted for public use is exempt from the requirement of section 26-4.01.01(c).
(f) Lot width shall be measured at the building line, parallel to the street right-of-way line.
(g) Impervious surface standards are expressed as the maximum percent of land coverage for each zoning district. The impervious surface ratio is calculated by dividing the total of all impervious surfaces on the lot by the lot area. Impervious surfaces include all buildings, structures, paving and water bodies.
(h) All lots shall front upon a dedicated public road or a private road meeting the requirements of this LDC, with the exception that an access corridor may be used in accordance with section 26-6.02.06(a) of this LDC.
(i) Side lot lines shall, as much as practical, be at right angles to straight street lines or radial to curved street lines and cul-de-sacs.
(j) All lots shall conform to the provisions of the LDC.
(k) Where individual septic tanks or other such on-site disposal facilities are to be used as a means of sewage disposal, the county health officer may require increases in the minimum lot size as necessary to conform to rules and recommendations of the state department of public health. In no case, however, shall the lot size be reduced to less than the required minimum as established in this section. Where extreme health hazards are indicated by site characteristics, the county health officer may disapprove the intended use of the lot or require special types of sewage disposal to be constructed as a prerequisite to a lot's being used.
(l) Cul-de-sac lots or eyebrows shall have a minimum width of lot frontage of 25 feet along the street right-of-way line and a minimum lot width of 75 feet.
(m) Access on all double frontage lots in residential subdivisions shall be restricted to the lesser used street or the street with the lowest hierarchy in the street classification system.
(n) Commercial uses on corner lots which have frontage on interior residential subdivision streets shall have access only from the higher-level street.
(o) The owner of lots zoned commercial, office, and institutional shall grant an access easement to each adjoining property that is zoned such for the purpose of improving connectivity between compatible uses. Access design shall be prepared by a design professional for review and approval by the planning commission in accordance with the procedures of this LDC.
(p) Lots that are conveyed from one family member to another shall adhere to the standards of section 26-4.04.04 specific provisions for family ties land division.
(q) Standards for lot area, width, and impervious surface coverage are set forth in Table 4-A.
Table 4-A Standards for Lot Area, Width and Impervious Surface Zoning District Minimum Lot Area* Minimum Lot Width at Building Line and Minimum Lot Frontage (feet) Maximum Impervious Surface Ratio Individual Well/Septic Tank System Public/Community Water and Individual Septic Tank System Public/Community Water and Public Sewer System Minimum Lot Width Minimum Lot Frontage A-1 5 ac. 5 ac. 5 ac. 150 ft. 150 ft. 25% R-1 1 ac. 1 ac. 30,000 sq. ft. 150 ft. 150 ft. 50% R-2 (including duplexes) 1 ac. 1 ac. 15,000 sq. ft. 100 ft. 75 ft. 50% R-3 Townhome N/A N/A 1 ac. 100 ft.*** 100 ft. 70% Apartment N/A N/A 5 ac. 100 ft. 100 ft. 70% Zoning District Minimum Lot Area* Minimum Lot Width at Building Line and Minimum Lot Frontage (feet) Maximum Impervious Surface Ratio Individual Well/Septic Tank System Public/Community Water and Individual Septic Tank System Public/Community Water and Public Sewer System Minimum Lot Width Minimum Lot Frontage R-4 10 ac. per development 1 ac. per lot 10 ac. per development ac. per lot 10 ac. per development 8,000 sq. ft. per lot 100 ft. 60 ft. 50% O-I 1 ac. 1 ac. 10,000 sq. ft. 150 ft. 100 ft. 75% C-C 1 ac. 1 ac. 10,000 sq. ft. 150 ft. 100 ft. 75% C-G 1 ac. 1 ac. 10,000 sq. ft. 150 ft. 100 ft. 75% I-1 20,000 sq. ft. 20,000 sq. ft. 20,000 sq. ft. 150 ft. 100 ft. 85% I-2 1 ac. 1 ac. 1 ac. 150 ft. 100 ft. 85%
I-3 N/A N/A N/A N/A N/A N/A
* Unusual topographical or soil conditions may necessitate larger minimum requirements for properties utilizing septic systems. Installation of septic systems is subject to the approval of the Burke County Health Department.
** Where minimum lot width requirement is 150 feet, a reduction to 100 feet is permissible when building/ structure is connected to an off-site central water supply (public or community water system).
*** Minimum individual width per townhome is 20 feet.
Historia
(Ord. No. 18-01, §§ 1, 2, 9-11-2018; Ord. No. 24-01, § 4, 11-12-2024)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.