Ir al contenido
Georgia Commons
Menú

Burke County · Ordenanza de zonificación

Part II - CODE OF ORDINANCES / Chapter 26 - LAND DEVELOPMENT CODE / Article IV - SITE DESIGN STANDARDS

26-4.02.02. Dimensional standards for building height and location.

Sobre este texto

  • As published by Municode, current through 2025-10-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Measures of setbacks.

(1) Front setbacks shall be measured from the edge of the public right-of-way to the wall of the building or structure.

(2) Side and rear setbacks shall be measured from the property line to the wall of the building or structure.

(b) Encroachments into required setbacks.

(1) Building features, such as steps, fire escapes, cornices, eaves, gutters, sills and chimneys may project not more than three feet beyond a required setback line, except where such projections would obstruct driveways which are used or may be used for access of service and/or emergency vehicles. An unenclosed front or side porch, portico or stoop in a residential zoning district shall be allowed not more than three feet beyond the required front yard setback.

(2) In the case of automobile service stations and similar uses which serve the motoring public, canopies shall be allowed over a driveway or walkway within the front yard not to extend from the principal building to a point any closer than 15 feet from the street right-of-way line. Such canopies shall provide a minimum 12 feet vertical clearance.

(c) Lots with multiple frontages. Buildings constructed on lots abutting the right-of-way of more than one street or road, regardless of whether said street or road is public or private, shall comply with the front yard setback requirements of the district on each frontage and all remaining property lines shall be considered side yards for setback purposes.

(d) Group projects. A group project two or more commercial, industrial, educational, medical, religious, or civic buildings to be constructed on a plot of land two acres, or more, such plot not to be subdivided) may be constructed provided:

(1) Such uses are limited to those permitted within the district in which the project is located;

(2) The overall density of land use is no higher, and the standard of open space is no lower than that permitted in the district in which the project is located;

(3) The distance of every building from the nearest property line shall meet the front yard setback and side yard requirements of the district in which the project is located;

(4) The building heights do not exceed the height limits permitted in the district in which the project is located.

(e) Maintenance of setbacks.

(1) No open space or yard established through standards for setbacks shall be encroached upon or reduced in any manner except as allowed herein the LDC.

Shrubbery, driveways, retaining walls, fences, curbs, and planted buffer strips shall not be construed to be an encroachment of yards.

(2) No part of any required yard, open space, or off-street parking or loading space shall be considered to be part of a required yard, open space, or off-street parking or loading space for any other building or structure or use.

(f) Exemptions.

(1) The setback requirements of this LDC for dwellings shall not apply to any lot where the average existing building setback line on lots located wholly or in part within 100 feet on each side of such lot, within the same block and zoning district, and fronting on the same side of the street as such lot, is less than the minimum setback required.

In such cases, the setback on such lots may be less than the required setback, but not less than the average of the existing setbacks on the aforementioned lots, and in no case less than ten feet from the street right-of-way.

(2) With the exception of height limitations identified in subsection (g) below, the height limitations of this article shall not apply to church spires, belfries, cupolas and domes not intended for human occupancy; monuments, water towers, observation towers, transmission towers, chimneys, smokestacks, conveyors, flag poles, radio towers, television towers, masts, aerials, silos, granaries, windmills, barns, and other structures concurrent to the operation of a commercial agricultural use, and similar structures.

(g) Height limitations surrounding public or private airports.

(1) All structures are subject to the air space control height and use restrictions surrounding airports, whether public or private.

(2) All airports public and private airports registered with the FAA shall maintain safe and appropriate takeoff and landing pathways, and shall not be encroached upon due to the height or placement of any structure.

(3) Any proposed structure shall not be permitted to penetrate any airspace surfaces, as defined in this section, on or near a public or private airport.

(4) Special attention shall be given to the following airspace areas surrounding public or private airports:

a. Approach surface. The approach surface is longitudinally centered on the extended runway centerline and extends outward and upward from the end of the runway. The approach surface extends 5,000 feet from the end of the runway at an approach slope of 20 feet horizontally for each one foot vertically (20:1). The inner edge of the approach surface (beginning at each end of the runway) is 250 feet wide, and expands uniformly to a width of 1,250 feet at a distance of 5,000 feet from the end of the runway.

b. Transitional surface. The transitional surface extends outward and upward at right angles to the runway centerline and extends at a slope of seven feet horizontally for each one foot vertically (7:1) from the sides of the runway and approach surfaces. The transitional surfaces extend to the point at which they intercept the horizontal surface at a height of 150 feet above the established airport elevation.

c. Horizontal surface. The horizontal surface is a horizontal plane located 150 feet above the established airport elevation and encompasses an area from the transitional surface to the conical surface. The perimeter is constructed by generating arcs of 5,000 feet in length from the center of each end of the runway surface and connecting the adjacent arcs by lines tangent to those arcs.

d. Conical surface. The conical surface extends upward and outward from the periphery of the horizontal surface at a slope of 20 feet horizontally for every one foot vertically (20:1) for a horizontal distance of 4,000 feet. Height limitations for the surface range from 150 feet above the airport reference elevation at the inner edge of the conical surface to 350 feet at the outer edge of the conical surface.

(h) Building setback and height standards are provided in Table 4-B.

Table 4-B Building Setback and Height Standards Zoning District Min. Setback from ROW* Min. Setback from Property Lines Max. Building Side Rear Height A-1 50 ft. 20 ft.** 50 ft.** 3 stories**** R-1 50 ft. 15 ft.*** 30 ft.*** 3 stories R-2 50 ft. 15 ft.*** 30 ft.*** 3 stories (duplexes limited to 2 stories) R-3 Townhome: 50 ft. 15 ft.*** 30 ft.*** 3 stories Apartments: 50 ft. 15 ft.*** 50 ft. 4 stories R-4 50 ft. 15 ft.*** 30 ft.*** 3 stories O-I 50 ft. 15 ft. 20 ft. 4 stories C-C 50 ft. 15 ft. 20 ft. 4 stories C-G 50 ft. 15 ft. 20 ft. 4 stories I-1 50 ft. 20 ft. 60 ft. 60 feet I-2 50 ft. 20 ft. 60 ft. 60 feet

I-3 N/A

* Min. setback is 100 ft. from centerline when no ROW exists.

** Additional setback requirements may apply. See article IV.

*** Side yard shall be a minimum of 25 feet when abutting an A-1 zoning district. Rear yard shall be a minimum of 50 feet when abutting an A-1 zoning district.

**** Silos, granaries, windmills, barns, and other structures concurrent to the operation of a commercial agricultural use may exceed three stories in height.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 18-01, §§ 1, 2, 9-11-2018; Ord. No. 24-01, § 5, 11-12-2024)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:burke-county/zoning/26-4.02.02@2025-10-14-6702d4de14

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Burke County Zoning Ordinance, 26-4.02.02. Dimensional standards for building height and location | Georgia Commons