Ir al contenido
Georgia Commons
Menú

Canton · Ordenanza de zonificación

Part III - DEVELOPMENT CODE / Chapter 111 - DESIGN STANDARDS: SEWER SYSTEM TABLE OF CONTENTS

111.03.09. Force mains.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

A. The force main shall be sized for a minimum velocity of two and one-half feet per second with one pump operating.

B. Force mains of four-inch diameter or larger shall be ductile iron pipe. Smaller force mains may be used only with grinder pumps and shall be PVC pipe, SDR-21 with gasket joints. PVC pipe shall not be exposed to sunlight or freezing temperatures. Buried PVC pipe shall be marked continuously with metallized locator tape.

C. The force main profile shall slope continuously upward where practical. If high points occur where air could be trapped in the pipe, then an air release valve (of the type made for sewage applications) will be installed (in a manhole) at the high points.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2014-18, § 2, 8-21-2014)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:canton/zoning/111.03.09@2026-11-11-cae1133d28

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Canton Zoning Ordinance, 111.03.09. Force mains | Georgia Commons