A. Height regulations. Buildings shall not exceed a height of seventy-five (75) feet, measured from structure pad level. Height limitations shall not apply to accessory structures such as water towers, conveyer belts, smokestacks and other incidental
and uninhabited parts of industrial uses.
B. Front yard setback: fifty (50) feet.
C. Side yard setback: fifty (50) feet.
D. Rear yard setback: fifty (50) feet.
E. Minimum lot frontage: One hundred ten
(110) feet adjoining a street.
F. Minimum lot width at the building line:
One hundred ten (110) feet.
G. Minimum lot acreage: Fifty (50) acres.
H. Minimum buffer requirements. In addition to required setbacks, a minimum 100-foot-wide buffer, which can include
required setback, shall be required along all property lines which abut a residential district or use in order to provide a visual screen in accordance with section 4.17 of this chapter.
I. Air conditioning units and HVAC systems.
Air conditioning units and HVAC systems shall be thoroughly screened from view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping. This requirement shall not apply where the
equipment is more than one hundred
(100) feet from adjacent property lines.
J. Front building facade. The front building facade of all principal buildings shall be oriented toward street fronts or adjacent arterial street fronts. This requirement shall not apply if the front of the building is greater than five hundred (500) feet
from the public right-of-way or not visible from the public right-of-way.
K. Security fencing. Security fencing and walls shall not be located within the
required buffer unless it complies with the general regulations pertaining to fencing. Fences and walls outside the required setback and buffer provided above shall
not be subject to height limitations.
L. Accessory structures. Accessory structures shall be subject to the general ordinances of the City code, provided that if they are to be located outside of the setbacks and buffers provided above, they shall not be subject to the location requirements of
section 4.9. Further, notwithstanding other provisions of the code, guard houses and secured entry features shall be
permitted at public road entrances.
M. Required setbacks and buffers shall only apply to external property boundaries
with other properties not zoned as part of the T district. Minimum lot frontages,
width and acreage shall not apply to subdivided T lots, so long as the entirety of the contiguous T district complies with the requirements of this ordinance, and
so long as the subdivided lot has adequate frontage on public or private roads to
allow service.
N. Private roads are permitted within the T district. They shall be designed and built subject to the design guidelines for City public roads.
O. Telecommunication towers shall be permitted to be installed in a manner consistent with the standards of Section
4.29 of this zoning ordinance.
P. Dark sky lighting. Exterior illumination shall be shielded, downcast and of a
luminosity designed to maintain the existing night sky darkness and to prevent light trespass onto adjacent properties.
In order to obtain that objective, the following criteria shall be met:
a. all fixtures shall be full cut-off type fixtures,
b. light poles shall be no taller than 25 feet in height,
c. all light poles must be setback a minimum of I 0 feet from any exterior property line
d. maximum foot-candles at the property line shall be 0.5 The zoning administrator may require a photometric lighting plan which shows conformity with these requirements as part of any building permit application.