As-builts shall be required before the final plat is recorded for subdivisions or before a certificate of occupancy issued for commercial/ industrial sites. All as-built drawings must be on standard twenty-four (24) inches × thirty-six
(36) inches sheets with a maximum scale of one
(1) inch = fifty (50) feet. Electronic files must also be submitted in AutoCAD format with water, sewer and storm system all on separate layers.
(a) The water system as-builts shall show locations of fire hydrants, line valves, tees, water main sizes, and types of
materials.
(b) The sanitary sewer system as-builts shall show locations of manholes, lines, services, line sizes, types of materials, manhole
inverts, and line grades.
(c) Street ands storm sewer as-builts shall show street layout, profiles, grades, storm sewers and sizes, storm drainage
structures, and detention ponds.
(d) Commercial site layout as-builts in addition to water, sanitary sewer, and storm sewer, as-builts shall include, but not
limited to, the following final locations of building(s), entrance(s), parking, and grading on computer disk in AutoCAD format (if feasible).
(e) Sprinkler system as-builts with head count.
Historia
(Ord. No. 32-98, § 1, 8-27-98; Ord. No. 68-04, § 6, 9-2-04)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.