Cordele · Ordenanza de zonificación
Appendix C - DEVELOPMENT REGULATIONS PEAK WATER DEMANDS FOR RESIDENTIAL DEVELOPMENTS / Article VI - GRADING AND DRAINAGE
Section 6.4. Preparation of grading and drainage plans.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Grading and drainage plans for all developments except individual one and/or two family dwelling units, shall be prepared by a Georgia registered professional engineer or landscape architect. At least three copies of the plans and detention study shall be submitted to the Department of Community Development for review and comment. Within thirty days of submittal of the plans, the Department of Community Development will either approve the plans or make comment on items requiring changes and/or additional information. When not approved, the cycle of plan submittal and review will be repeated until the plans can be approved by the Department.
Information to be shown on the plans shall consist of not less than the following:
(a) Topographic map of the existing conditions for the development showing existing facilities and features which affect or could be affected by grading and drainage improvements. Utilize a contour interval of not greater than two feet with spot elevations as necessary to define existing ground surfaces.
(b) All drainageways, lakes, streams, creeks, swales, ditches, channels, wetlands, and drainage facilities.
(c) All existing utilities and appurtenances which affect or could be affected by grading and drainage improvements. The utility type, size and location in relation to grading and drainage improvements should be indicated.
(d) Existing and proposed property and easement lines and land lot and land district lines intersecting or bounding grading and drainage improvements.
(e) Finished grades depicted by finished contours and/or spot elevations as necessary to define finished grade surfaces.
(D New drainage improvements including, but not limited to, pipes, culverts, catch basins, area drains, drop inlets, junction boxes, headwalls, berms, dikes and detention basins with outlet works. The drainage areas tributary to each drainage structure, design flow, and time of concentration shall be indicated.
(g) Profiles of storm drains showing existing and finished ground surfaces, pipes, drainage structures with top and flow line elevations, distances from centerline to centerline of drainage structures, pipe and ditch grades, crossing utilities, and limits of special construction.
(h) Benchmarks for vertical control.
(i) Name of the development, names, addresses and telephone numbers of developer and developer's design professional, design professional's seal, north arrow, scale and date.
Plans shall be prepared in conformance with the following:
(a) All elevations shall be based on and tied to U.S. Coast and Geodetic Survey mean sea level datum.
(b) Plan drawings shall be at a scale of at least 1 inch equals 100 feet. In developed or congested areas, a scale of 1 inch equals 20 feet or less shall be utilized.
(c) For profile drawings, the horizontal scale shall be the same as that used for the associated plan drawings. The vertical scale shall be a the least 1 inch equals 10 feet.
A 1 inch equals 5 feet vertical scale is often necessary to properly depict drainage conditions.
(d) The desired drawing size is 24 inches by 36 inches. In no case shall drawings be larger than 30 inches by 42 inches nor smaller than 11 inches by 17 inches.
(e) Drainage construction may be shown on street or utilities improvements plans provided the resulting drawings are clear, legible and plainly show all necessary information.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.