Ir al contenido
Georgia Commons
Menú

Fayette County · Ordenanza de zonificación

Part II - COUNTY CODE / Part B - LAND DEVELOPMENT AND LAND USE / Chapter 104 - DEVELOPMENT REGULATIONS / Article IV - FLOODPLAIN MANAGEMENT

Sec. 104-87. Provisions for flood damage reduction.

Sobre este texto

  • As published by Municode, current through 2026-05-28
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

In all areas of special flood hazard and all areas of future-conditions flood hazard, the following provisions apply:

(a) General standards.

(1) New construction and substantial improvement of structures (residential or nonresidential), including manufactured homes, shall not be allowed within the limits of the future-conditions floodplain, unless all requirements of subsection (g) of this section and sections 104-86(a) and 104-88(e) have been met;

(2) New construction and substantial improvements shall be anchored to prevent flotation, collapse and lateral movement of the structure;

(3) New construction and substantial improvements shall he constructed with materials and utility equipment resistant to flood damage;

(4) New construction and substantial improvements shall be constructed by methods and practices that minimize flood damage;

(5) Elevated buildings. All new construction and substantial improvements that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls shall be designed as an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater.

a. Designs for complying with this requirement must either be certified by a licensed professional engineer or architect to meet or exceed the following minimum criteria:

1. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding;

2. The bottom of all openings shall be no higher than one foot above grade; and

3. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both directions.

b. So as not to violate the "lowest floor" criteria of this article, the unfinished and flood resistant enclosure shall solely be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; and

c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms.

(6) All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be designed and/or located three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher, so as to prevent water from entering or accumulating within the components during conditions of flooding;

(7) Manufactured homes shall be anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces;

(8) New and replacement water supply systems shall be designed to minimize to eliminate infiltration of floodwaters into the system;

(9) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters;

(10) On-site waste disposal systems shall be located and constructed to avoid impairment to or contamination from such systems during flooding;

(11) Any alteration, repair, reconstruction or improvement to a structure that is not compliant with the provisions of this article, shall be undertaken only if the nonconformity is not furthered, extended or replaced;

(12) If the proposed development is located in multiple flood zones or multiple base flood elevations cross the proposed site, the higher or more restrictive base flood elevation or future condition elevation and development standards shall take precedence;

(13) All proposed development shall include adequate drainage and stormwater management facilities per the requirements of article XIV, Fayette County Development Regulation to reduce exposure to flood hazards;

(14) Public utilities, such as gas and electric systems, shall be located and constructed to minimize or eliminate flood damage or public safety hazards;

and

(15) When only a portion of a proposed structure is located within a flood zone or the future-conditions floodplain, the entire structure shall meet the requirements of this article.

(b) Building standards for structures and buildings within the future-conditions floodplain. The following provisions, in addition to those in subsection (a) of this section, shall apply:

(1) Residential and nonresidential building structures.

a. New construction of any structure shall not be allowed within the limits of the future-conditions floodplain unless all requirements of subsection

(g) of this section and sections 104-86(c) and 104-88(e) have been met. If all of the requirements of subsection (g) of this section, and sections 104-86(c) and 104-88(e) have been met, all new construction shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection (a)(5) of this section. A licensed professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the environmental management department.

b. Substantial improvement of any structure shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection (a)(5) of this section. A licensed professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the Environmental Management Department.

c. Accessory structures and facilities. Accessory structures and facilities (i.e., barns, sheds, gazebos, detached garages, recreational facilities and other similar nonhabitable structures and facilities) which meet the requirements of sections 104-86(c), 104-88(e) and 104-87(g) and are permitted to be located within the limits of the future-conditions floodplain shall be constructed of flood-resistant materials and designed to provide adequate flood openings in accordance with subsection (a)(5)(a) of this section and be anchored to prevent flotation, collapse and lateral movement of the structure.

(2) [Reserved.]

(3) Standards for recreational vehicles. All recreational vehicles placed on sites must either:

a. Be on the site for fewer than 180 consecutive days and be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or

b. Meet all the requirements in subsection (b)(1) of this section, including the anchoring and elevation requirements.

(4) Standards for manufactured homes.

a. New manufactured homes shall not be allowed to be placed within the limits of the future-conditions floodplain unless all requirements of subsection (g) of this section and sections 104-86(e) and 104-88(e) have been met. If all the requirements of these sections have been met, all new construction and substantial improvement shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with section 104-87(5)a.

b. Manufactured homes placed and/or substantially improved in an existing manufactured home park or subdivision shall be elevated so that:

1. The lowest floor of the manufactured home is elevated no lower than three feet above the level of the base flood elevation, or one foot above the future-conditions flood elevation, whichever is higher;

and

2. The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade.

c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement in accordance with standards of subsection (a)(7) of this section.

(c) Building standards for structures and buildings authorized adjacent to the future-conditions floodplain. For purposes of this article, the term "adjacent to the future-conditions floodplain" includes: all buildings and structures on a property that contains (partially or entirely) an area of special flood hazard; or all buildings and structures on a property that shares a common property line with another parcel that contains an area of special flood hazard. Residential and nonresidential buildings and structures adjacent to the future-conditions floodplain shall meet the following:

(1) For new and substantial improvement construction, the elevation of the lowest floor, including basement and access to the building, shall be at least three feet above the base flood elevation or one foot above the futureconditions flood elevation, whichever is higher. Compliance with the above requirement shall be submittal of an as-built elevation certificate and submitted immediately upon completion of floodproofing or survey work. The elevation certificate shall be prepared by or under the direct supervision of a registered land surveyor or professional engineer and certified by the same.

a. Buildings and structures authorized adjacent to the future-conditions floodplain may be exempt from the requirements of this section if the following conditions apply:

1. The building or structure is not within the same sub-basin as the area of special flood hazard and the drainage divide between the area of special flood hazard and the building or structure of concern is at least three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher; or

2. The area of special flood hazard is a manmade hazard associated with a storm sewer system (e.g., a yard drain) and the grading within the sub-basin provides unconstrained, positive drainage away from the building or structure at a minimum slope of two percent.

b. The environmental management department shall determine if either of these conditions is applicable to a structure. Alternatively, the owner/ developer may provide a letter justifying applicability of the exemptions.

The letter shall be prepared by a licensed professional engineer and shall be reviewed and approved by the environmental management department in order for the exemption to be valid. In either case, the owner/applicant shall be solely responsible for providing any as-built elevation data necessary to determine applicability of the exemptions.

The elevation data shall be prepared by or under the direct supervision of a licensed land surveyor or professional engineer and certified by the same.

(d) Building standards for residential single-lot developments on streams without an established base flood elevations and floodway (A-zones). For a residential single-lot development not part of a subdivision that contains an area of special flood hazard, where streams exist but no base flood data have been provided (A-zones), the environmental management department shall review and reasonably utilize any available scientific or historic flood elevation data, base flood elevation and floodway data, or future-conditions flood elevation data available from a federal, state, local or other source, in order to administer the provisions and standards of this article. If data are not available from any of these sources, the following provisions shall apply:

(1) No encroachments, including structures or fill material, shall be located within an area equal to twice the width of the stream or 50 feet from the top of the bank of the stream, whichever is greater.

(2) In special flood hazard areas without base flood or future-conditions flood elevation data, new construction and substantial improvements shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the ground immediately around the building and positive drainage must be provided at a minimum two percent slope away from the building. Flood openings sufficient to facilitate automatic equalization of hydrostatic flood forces shall be provided for flood prone enclosures in accordance with subsection (a)(5) of this section.

(e) Standards for subdivisions.

(1) All subdivision proposals shall identify the areas of special flood hazards and provide base flood elevation data and future-conditions flood elevation data;

(2) All residential lots in a subdivision proposal shall have sufficient buildable area outside of the future-conditions floodplain such that encroachments into the future-conditions floodplain for residential structures will not be required;

and

(3) All subdivision plans will provide the elevations of proposed structures in accordance with section 104-88(b).

(f) Floodway encroachments. Located within areas of special flood hazard are areas designated as floodway. A floodway may be an extremely hazardous area due to the velocity of floodwaters, and debris or erosion potential. Floodways must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply:

(1) Encroachments are prohibited, including earthen fill, new construction, substantial improvements or other development within the regulatory floodway, except for activities specifically allowed in subsection (g)(2) of this section;

(2) Encroachments for bridges, culverts, roadways and utilities within the regulatory floodway may be permitted provided it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practices that the encroachment shall not result in any increase to the pre-project base flood elevations, floodway elevations, or floodway widths during the base flood discharge. A licensed professional engineer must provide supporting technical data and certification thereof; and

(3) If the applicant proposes to revise the floodway boundaries, no permit authorizing the encroachment into or an alteration of the floodway shall be issued by the environmental management department until an affirmative conditional letter of map revision (CLOMR) is issued by FEMA or a no-rise certification is approved by the environmental management department.

(g) Maintenance requirements. The property owner shall be responsible for continuing maintenance as may be needed within an altered or relocated portion of a floodplain on the property so that the flood-carrying or flood storage capacity is maintained. The environmental management department may direct the property owner (at no cost to the county) to restore the flood-carrying or flood storage capacity of the floodplain if the owner has not performed maintenance as required by the approved floodplain management plan on file with the environmental management department.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2015-07, § 1, 4-23-2015; Ord. No. 2024-09, § 1, 10-24-2024)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:fayette-county/zoning/104-87@2026-05-28-295ac3efda

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.