Unless modified by other provisions of this article or exempted under this article, all lighting shall comply with the following design standards:
(1) All exterior lighting fixtures on properties within the Military Lighting Overlay District in the City of Harlem with bulbs producing more than 1,000 lumens must be full cut-off or shielded and directed downward.
(2) All lighting shall have a maximum correlated color temperature (CCT) of 4000 Kelvin (K).
(3) All light coming from anywhere on the property may not exceed one-half foot candle of intensity at the property line of abutting residentially zoned property.
(4) Wall pack fixtures shall be full cut-off.
(5) Unshielded sag-lens, drop lens, or mercury vapor fixtures are prohibited.