(a) All developments within the city require a site analysis, a comprehensive site plan and an architectural design plan. Any design plan for a development estimated to cost in excess of $50,000.00 shall require either an architect or engineer's stamp as appropriate to the project.

(On completion of construction of the development, the architect or engineer shall be required to certify compliance with the design plan as approved.) Additionally, developments within areas of special flood hazard require a hydrological study and engineer's certification in conformity with article VI. These initial design requirements must be submitted to the planning and design review board before any permit applications are submitted for approval.

(b) A current design review package, available from city hall, shall be obtained and completed, as applicable, before the project is initially presented to the planning and design review board.

(c) Design standards shall be followed by an applicant according to the following criteria:

(1) Roof. The primary roof of all new structures and any existing structure for which a modification of 50 percent of the existing exterior dimensions in lineal perimeter is planned shall have a minimum roof pitch of no less than six feet of rise per 12 feet of run (6

/12 pitch). The primary roof shall be covered with red fiberglass shingles. Any towers, bay windows or other adjunct parts of the structure may be covered with red shingles, copper or standing seam metal roofing when approved by the planning and design review board.

(2) Exterior and interior trim. The trim of all exterior building surfaces and publicly exposed interior building surfaces is regulated as follows for any new building or a proposed alteration to a building for which a modification of 25 percent of the existing usable square footage or for which an expenditure of more than $10.00 is planned.

Trim standards shall meet design motif on all fascia.

(3) Glass window surface as a percentage to total exposed wall surface for each building elevation. The permitted maximum percentage of glass window surface in square feet shall be regulated in proportion to the total wall surface of each building elevation plan at the discretion of the planning and design review board. However, in no event shall the permitted maximum percentage of glass window surface exceed 40 percent of the total wall surface. (The total wall surface shall include any area proposed for use as a glass window or door.)

(4) Building scale. The scale of all new construction or 50 percent modification to an existing building as may be determined by additions to lineal perimeter distance of the exterior walls may follow a maximum seven-eighths scale to full size (7 /8 scale) on all

front and side exterior elevations.

(5) Building contiguity. The application for a building permit shall include a proposed design for the physical connection of the proposed building to any building and each elevation that may be on the same lot or on adjoining lots, whether or not such lots may be owned by the applicant. Such design shall include connections by extended wall lines, connected roof lines, or connected balconies and walkways. The purpose of contiguity is the facilitation of maximum ease in pedestrian access while maintaining a unity in design.

(6) Lighting standards. Illuminescence shall be regulated as follows:

a. Exterior mounted lights may be of any type except neon. Except for gas lights, all other exterior lights shall be shielded to prevent direct lighting exposure to public view.

b. Interior lights may be of any type. Except for gas or kerosene lights, all other interior lights shall be shielded to prevent direct lighting exposure to public view.

Additionally, interior neon lights shall not be placed in windows or otherwise displayed so as to be visible from the street, sidewalk or other public rights-ofway.

c. The lighting standards referenced in this subsection shall not apply to internally illuminated signage which has been approved by the city in accordance with the requirements of chapter 34, article VII, Signs.

(7) Building colors. The exterior colors of buildings shall be one or more of the colors shown on Ace Paint Exterior Colors for Your Life color chart (you may use any manufacturer's paint as long as colors match the approved colors in the referenced color chart). A copy of this color chart is maintained in Helen City Hall.

(8) Window and door design. Exterior and interior windows and doors shall be regulated as follows:

a. Windows: minimum number of grid sections per installed frame: 4.

b. Doors: minimum number of panels per installed frame: 2.

Prohibited door types: thin rail shutters, sliding partition made from vinyl or similar cloth material, hollow core, solid core single panel (trim can be applied to solid core single panel door to create two or more panel effect).

(9) Roof overhang, balcony overhang and portico standards. The overhang of roofs, balconies and porticos shall be regulated as follows:

a. Roofs: minimum roof overhang: 36 inches; maximum roof overhang: six feet.

b. Balconies: minimum balcony overhang: four feet; maximum balcony overhang:

nine feet. Balcony shall be cross-hatched beneath the top rail or filled in an alpine design.

c. Minimum portico overhang: two feet; maximum portico overhang: six feet.

Porticos must be a gable design. Shed roofs are prohibited.

(10) HVAC equipment and utility meters. All HVAC equipment, including vents, and utility meters shall be enclosed or otherwise rendered unobtrusive, and be reasonably protected against damage. However, utility meters must be left accessible for servicing and reading.

(11) Handicapped accessibility. See section 34-801 for construction standards.

(12) Water conservation standards. See section 70-35 for maximum flow rates of plumbing fixtures and trim.

(13) General motif. The general motif for commercial developments shall be Alpine design as shown in the city of Helen, Georgia Architectural Guidelines, prepared by Hill Studio, P.C., dated September 27, 1994.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Code 1987, § 14-201; Ord. No. 92-7, 12-15-92; Ord. No. 96-09-01, 10-31-96; Ord. No. 08-10-02, 11-18-08; Ord. No. 12-08-01, 9-18-12; Ord. No. 14-01-01, 2-18-14)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.