Sec. 34-577. Fire sprinkler systems.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Commercial fire sprinklers. All new commercial construction shall be equipped with automatic fire sprinkler systems installed according to National Fire Protection Standard 13, latest edition as adopted by the State of Georgia, where required by NFPA Life Safety Code 101 or Standard Building Code, due to size or use. All other buildings not meeting the NFPA 13 Code criteria may elect to use the Cobb County, Georgia Standard for the installation of sprinkler systems in small commercial buildings as adopted by the City of Helen (reference Appendix A to Ordinance No. 94-02-2), with the exception of the following:

(1) Detached unenclosed structures of less than 210 square feet, i.e., pavilion, deck.

(2) Detached one-story noncombustible unenclosed covered vehicle storage areas, maintaining a minimum of 30 feet of open separation from any structure, with no storage capabilities and which is less than 1,000 square feet.

(b) Multi-family residential fire sprinklers. All new multi-family residential construction of three or more attached units, exclusive of one and two family dwellings, shall be equipped with automatic fire sprinkler systems installed according to the requirement of the National Fire Protection Standard 13R, latest edition as adopted by the State of Georgia, with the same exceptions as found in section 34-577(a)(l) and (2).

(c) Maintenance and testing of sprinkler systems. All new and existing sprinkler systems must be maintained and tested annually, according to NFPA Fire Protection Standard 25 or SBCCI Standard Fire Prevention Code Section 603, latest edition as adopted by the State of Georgia, by a sprinkler contractor who holds a certificate of competency issued by the state fire marshal1s office. Written notification of the results of annual tests must be forwarded on such forms as the fire marshal may require, to the fire marshal's office within 30 days of the test, with the exception of the following:

(1) Systems installed in one and two family dwellings under NFPA 13D regulations.

(2) Any time a deficiency is found or reported concerning a sprinkler system, a test or maintenance can be immediately required by the fire chief or fire marshal.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 89-13, § 14-204, 1-16-90; Ord. No. 94-02-2, 3-15-94)