Sec. 50-94. Building standards for areas of special flood hazard (AE-zones) with established base flood elevations and without designated floodway.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

Located within the areas of special flood hazard established in section 50-36, where streams with base flood elevations are provided but no floodway has been designated, (AE-zones), the following provisions apply:

(1) No encroachments, including fill material, new structures or substantial improvements shall be located within areas of special flood hazard, unless:

a. Any fill material or portion of any other improvement placed inside a special flood hazard area (SFHA) below base flood elevation shall be mitigated on site or on an adjacent site by an equal to or greater volume of excavated material.

The mitigation excavation must be connected to the SFHA at an elevation less than or equal to an elevation two feet below the 100-year flood plain elevation or the stormwater conveyance system shall be sized and constructed to convey the 100-year 24-hour storm to a suitable outfall.

If subsection (a) above is unable to be met, subsection (b) shall apply.

b. Certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood at any point within the community. The engineering certification should be supported by verifiable technical data that conforms to standard hydraulic engineering principles.

(2) New construction and substantial improvements shall be elevated or flood-proofed to elevations established in accordance with section 50-92.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. O2025-01.A, § III, 3-18-2025; Ord. No. O2025-06.D, § II, 7-21-2025)

Reuniones que se refieren a esta sección

Encontradas: 1. Son reuniones de este gobierno cuyas actas o transcripciones automáticas nombran esta sección, o una ordenanza de su línea de historia, de la más reciente a la más antigua. Halladas por regla a partir de las propias palabras de esos registros. Una referencia es un enlace a otro registro, no una afirmación de que la sección se aplica o se cambió.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:pooler/code/50-94@2026-11-11-d9aa0efbb0

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Pooler Code of Ordinances, Sec. 50-94. Building standards for areas of special flood hazard (AE-zones) with established base flood elevations and without designated floodway | Georgia Commons