A. The size, length, and location of all surface drainage pipe or structures shall be shown on all preliminary plats. All storm drain pipes or culverts carrying stormwater from the street and adjacent property or through lots in the subdivision shall be extended to ten (10) feet from the rear property line. Stormwater shall be released into a channel or swale without causing scouring, erosion, or resulting in sedimentation of the receiving channel. The outlet channel shall include structural and vegetative measures to assure nonerosive velocities of stormwater.
B. Installations, backfilling, and compaction around drainage pipes shall be in accordance with Georgia Department of Transportation (GDOT) specifications. All pipes shall have a minimum cover of eighteen (18) inches from the bottom of the road base, and head walls or inlet basins constructed at the ends of the pipes.
C. The design of drainage structures shall be based on recognized hydrological formulae.
D. Piped collection systems for public streets (catch basins, inlets, cross drains, longitudinal piping), shall be designed for the fifty-year storm.
E. Road culverts, which carry live streams, shall be RCP and off-site drainage shall be designed for the one hundred-year storm and the developer's engineer is to provide a no-rise certification letter.
F. Cross drainpipes within the public rights-of-way shall be designed and constructed at or near a ninety (90) degree angle with the roadway centerline. Where a slight skew is necessary, the pipe shall be placed within an eighty- to one hundred-degree angle with the roadway centerline.
G. Longitudinal pipes along a curved section of roadway shall be located on the inside of the curve to avoid pipe beneath the roadway footprint. In the event that the longitudinal pipe needs to be along the outside of the curve, the pipe shall be wholly located outside the limits of the curb and gutter by use of additional junction boxes. For pipe at a cul-de-sac location, all pipe shall be wholly located outside of the footprint of the curb and gutter that encircles the cul-de-sac.