1. No existing or proposed cut or fill slopes shall be steeper than two horizontal units to one vertical unit.
2. All fill slopes created for the purpose of street or home construction shall have a compaction of not less than 95 percent standard proctor, as determined by established engineering practices.
3. All slopes created or existing within the subdivision or as a result of the subdivision development shall be planted or otherwise protected from erosion and failure.
4. No cut or fill slopes or existing unadjusted slope shall encroach closer than eight feet from the edge of pavement on any street right-of-way within the subdivision.