Dry detention ponds shall be designed to provide for positive drainage on the pond floor to the outlet of the pond with a minimum of a 2 percent slope. Side slopes for the dam shall be designed to have a maximum of 3-feet horizontal to 1-foot vertical (3:1) slopes.
A six foot chain link fence will be required for above ground stormwater detention facilities that exceed six feet in depth measured from the outlet invert to the top of the berm. In the front yard, the fence height may be reduced to four feet. The fence shall include a double drive-thru gate of sufficient size to permit entrance of equipment necessary to allow periodic maintenance activities. A chain link fence will not be required when the site in which the pond is to be constructed is zoned non-residential and is more than 1,000 feet from properties zoned residential or publicly owned property (excluding right-of-way).
Acceptable backfill and fill materials shall consist of suitable soils for dam construction as determined by the county engineer; free of rock or gravel larger than one inch in any dimension, debris, waste, frozen materials, vegetation, and other deleterious matter. Backfill and fill materials should be placed in layers not more than eight inches in loose depth for material compacted by heavy compaction equipment, and not more than four inches in loose depth for material compacted by hand-operated tampers. Each layer should be uniformly moistened or aerated before compaction to within three percent of optimum moisture content. Layers should not be placed on surfaces that are muddy, frozen, or contain frost or ice. All backfill and fill materials should be placed evenly to required elevations, and uniformly along the full length of the embankment. Additionally, soils should be compacted to at least 95 percent maximum dry unit weight according to ASTM D 698.