Whitfield County · Ordenanza de zonificación
Appendix C - STORMWATER LOCAL DESIGN MANUAL
8.5.1. Stormwater management system map.
Sobre este texto
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
The stormwater management system map should document the various structural components of how stormwater runoff will be moved around the site.
• Location of all non-structural stormwater controls.
• Location of all existing stormwater controls to remain after development.
• Location of all proposed stormwater controls.
• Location of all proposed impoundment type controls (i.e. detention ponds, stormwater ponds, stormwater wetlands, etc.).
• Location of all conveyance structures.
• All impoundment type controls should be labeled with the following information:
• Maximum water surface elevation
• Depth and storage volumes for the design storm
• Depth and storage volumes maximum water surface if the design storm event is exceeded (i.e.
top of dam)
• All inlets to conveyance structures should be labeled with the following information:
• Maximum design water surface
• Maximum potential water surface
• All pipes should be labeled with:
• Length
• Material
• Slope
• All pipes should be profiled and labeled with:
• Length
• Material
• Slope
• Hydraulic grade line
• Map showing all contributing drainage areas/sub-basin delineations.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.