Ir al contenido
Georgia Commons
Menú

Brantley County · Código de ordenanzas

Part II - CODE OF ORDINANCES / Chapter 42 - FLOODS / Article III - PROVISIONS FOR FLOOD HAZARD REDUCTION

Sec. 42-61. General standards.

Sobre este texto

  • As published by Municode, current through 2025-04-03
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

In all areas of special flood hazard, the following provisions are required:

(1) New construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure.

(2) Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-thetop or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces.

(3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

(4) New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage.

(5) Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.

(6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system.

(7) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters.

(8) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding.

(9) Any alteration, repair, reconstruction or improvements to a building which is in compliance with the sections of this chapter shall meet the requirements of new construction as contained in this article.

(10) Any alteration, repair, reconstruction or improvements to a building which is not in compliance with the sections of this chapter shall be undertaken only if the nonconformity is not furthered, extended or replaced.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 9-13-1988, art. 5, § A)

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:brantley-county/code/42-61@2025-04-03-cd0cb9c2ee

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Brantley County Code of Ordinances, Sec. 42-61. General standards | Georgia Commons