(a) Residential lots fronting a minor road, cul-de-sac, or residential collector and having the point of egress and ingress with the minor road, cul-de-sac, or residential collector shall comply with the following:
(1) Insofar as practical, side lot lines shall be perpendicular or radial to streetlines; and every lot shall have a minimum of 60 feet of frontage on a minor street, except for cul-de-sac frontage which shall be 45 feet minimum.
(2) Residential lots shall have a depth of not less than 150 feet, unless circumstances make these limitations impracticable.
(3) No lot within a subdivision shall be approved that constitutes an unconventional lot.
(4) The subdividing of land shall be such as to provide each lot with direct abutting access to an existing minor street or to a street contained within the proposed subdivision.
(5) Where the subdivision abuts a state or county road, the subdivider shall construct a minor street to access all double frontage and reverse frontage lots (i.e., lots having street frontage both in front and rear). When extraordinary, exceptional, or peculiar conditions exist for a particular tract of land, an administrative decision may be granted for driveway connections. In any case, drive connections shall be placed to meet the visibility requirements of this article and provide the maximum sight distance available for the tract.
(6) In residential subdivisions abutting a state or county road, the subdivider shall establish a no-access easement of at least ten feet in width to the lots abutting the state or county road, across which there shall be no right of access to the state or county road. In the no-access easement, the subdivider shall plant a single line of shrubs or trees, or construct a decorative fence, or other such treatment as may be proposed and approved by the engineer.
(7) Corner lots shall have extra width to permit appropriate building setback from, and orientation to both streets. Corner lots shall have driveways on only one street.
(8) Lot remnants (lots below minimum area or width left over after subdividing tracts of land) shall be prohibited. Such remnant areas shall be added to adjacent lots, rather than remain as unusable parcels.
(9) The subdividing of land adjacent to or surrounding an existing or proposed lake, shall be such that lots abutting the lake shall be drawn to the centerline of the lake. Such requirements may be waived upon submittal to the engineer of an acceptable method for the maintenance of the lake and any recreational operations to be provided thereon.
The portion of any lot within a one-hundred year floodplain or covered by water or having a slope of 35 percent or greater shall not be included within the lot area used for determining the minimum required area of each lot.
(b) Commercial lots fronting a minor road, cul-de-sac, or commercial collector and having the point of egress and ingress with the minor road, cul-de-sac, or commercial collector shall comply with the following:
(1) Size, shape and arrangement of commercial and industrial lots, where platted, shall be subject to the approval of the engineer.
(2) The subdividing of land shall be such as to provide each lot with direct abutting access to an existing minor street or to a street contained within the proposed subdivision.
(3) Where the subdivision abuts a state or county road, the subdivider shall construct a minor street to access all double frontage and reverse frontage lots (i.e., lots having street frontage both in front and rear). When extraordinary, exceptional, or peculiar conditions exist for a particular tract of land, an administrative decision may be granted for driveway connections. In any case, drive connections shall be placed to meet the visibility requirements of this article and provide the maximum sight distance available for the tract.
(4) Lot remnants (lots below minimum area or width left over after subdividing tracts of land) shall be prohibited. Such remnant areas shall be added to adjacent lots, rather than remain as unusable parcels.
(5) The subdividing of land adjacent to or surrounding an existing or proposed lake, shall be such that lots abutting the lake shall be drawn to the centerline of the lake. Such requirements may be waived upon submittal to the engineer of an acceptable method for the maintenance of the lake and any recreational operations to be provided thereon.
The portion of any lot within a one-hundred year floodplain or covered by water or having a slope of 35 percent or greater shall not be included within the lot area used for determining the minimum required area of each lot.
(c) Obstructing visibility at intersections. On any corner lot, within an area formed by the lot lines on the street sides of such lot and a line (miter) on the street sides of such lot and a line (miter) joining points on such lot lines located at a distance of 20 feet from the point of the intersection, the following shall apply:
(1) There shall be no fence, wall or hedge higher than three feet.
(2) There shall be no obstruction to vision, other than a post or column or tree (except that erected by the county) not exceeding one foot in greatest cross-sectional dimension, between a height of 15 feet above the established grade of either of the intersecting streets.
(3) Notwithstanding the preceding, no fence, wall, hedge, shall be permitted along the street sides of corner lots where such fence, wall, hedge, or other obstruction would impair the visibility of traffic and traveling public.
(d) Driveways.
(1) Lot arrangements and minor street systems shall be designed in subdivisions so as to eliminate the need for driveway cuts from any lot to an existing state or county road.
(2) Driveways shall be designed and arranged to access minor streets. If access must be obtained from a state or county road, the driveway shall be designed and arranged to avoid requiring vehicles to back into traffic. If a driveway is to access a state or county road, the physical location of the driveway shall meet or exceed the distances and spacing between existing driveways and roads as set forth in the table below.
Roadway Speed Limit Distance and Spacing Requirement 55 miles per hour (mph). . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 feet 50 miles per hour (mph). . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 feet 45 miles per hour (mph). . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 feet 40 miles per hour (mph). . . . . . . . . . . . . . . . . . . . . . . . . . . . 325 feet 35 miles per hour (mph). . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 feet 30 miles per hour (mph). . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 feet
(3) When a residential lot has multiple frontages, the driveway cut(s) shall be located on the street with the lowest functional classification or the street having the lowest traffic count.
(4) The sharing of curb cuts by lots shall be limited to two dwelling units. The sharing of private access ways shall be shall be limited to two dwelling units.
(5) Driveways shall generally intersect streets at right angles.
(6) Driveways shall be constructed so as to have no more than a 5% upward grade. For those drives not meeting this requirement, a distance of 40 feet from the right-of-way shall be paved and sloped to direct drainage into ditches and away from the street pavement so as to not present a hazard to life or safety. The paved portion of a driveway shall be maintained by the owner.
(7) Driveways serving single-family and duplex residences may be no less than 15' wide at the right-of-way line and shall provide a radius to the back of the curb or edge of pavement of the roadway of no less than 5'.
(8) Multiple family residential driveways and drives serving all nonresidential land uses shall be designed and arranged to avoid requiring vehicles to back into traffic on all streets.
(9) In non-residential developments, interparcel access shall be required to facilitate movement between and among parcels adjoining a state or county road, to improve overall safety. However, when the natural grade along a common property line exceeds 15% throughout its length, such access shall be at the option of the property owners.
(10) Driveways and access ways for multi-family, office, commercial, and industrial developments are prohibited from accessing single-family residential streets unless approved by the engineer.
(11) When an existing or proposed commercial or industrial lot has frontage on more than one street and the nature of the business requires as a necessary accompaniment the use of vehicles over six wheels, the use of said vehicles over six wheels may be prohibited from using the lower functional streets. If the use of vehicles over six wheels on the lower functional streets contributes to and increases traffic flow on said lower functional streets, the engineer may require the existing commercial or industrial business to provide an additional driveway cut(s) so as to lighten, lessen, or relieve the use and flow of vehicles over six wheels on said lower functional streets.
(e) Streetlights. Streetlights shall be installed by the subdivider for all developments having more than 24 lots. All street light installation and maintenance shall be in accordance with this subsection.
(1) Intention. It is the intention of this subsection (e) to encourage good lighting practices to conserve energy, to minimize glare, to protect the use and enjoyment of surrounding property, and to increasing nighttime safety, utility, security and productivity. It is not the objective to illuminate adjoining private property.
(2) At the time of and as a requirement of submission of a preliminary plat, the subdivider shall:
a. Present a proposed streetlight layout that details the proposed streetlight service for the development with the conceptual plan or preliminary plat of the development, whichever shall first occur. The proposal shall meet all design standards set forth herein. All fixtures and standards/poles installed or to be used shall be approved by the county and the utility providing electrical service to the streetlights. All such fixtures shall meet IES standards. Should the engineer disapprove the streetlight layout, the grounds for disapproval shall be communicated in writing to the developer. Any such disapproval by the engineer may be appealed to the director under section 86-105 of this chapter.
b. Street lights shall have a high pressure "sodium" with a maximum of 10,000 lumen, unless a larger size lamp is needed for highway safety purposes and/or road intersections, as determined by the engineer.
c. Spacing between the lights will vary from 250 feet to 500 feet, or approximately every other utility pole.
d. The engineer shall not approve a final plat unless the subdivider submits proof of final payment to the utility company for construction and installation of the streetlights in the district, or a portion thereof where the development is phased.
(3) Lights in or near public right-of-way. All lighting fixtures within or near the public rights-of-way shall be installed and operated in such a manner so as to prevent interference with the normal use of the public rights-of-way in any manner, including glare, location of blinds, and other such means of potential interference. The approval of the engineer shall be necessary before any person shall be authorized to install a security light or other such lighting fixture within the public right-of-way.
(4) Special tax district. Where streetlights are required by this subsection (e), the subdivider shall apply to the county to establish a special tax districts for the provision of services of streetlight services within the development. The application for a special tax jurisdiction shall be reviewed and considered in accordance with the special tax district ordinance. The subdivider must receive the approval and designation of a special tax district prior to final plat approval.
(f) Greenspace. Greenspace shall be constructed, installed, and improved to meet the standards of the director and those customarily used and applied. Greenspace shall be subject to the following minimum standards.
(1) Minimum width. For accessibility, the width of any greenspace tract should be, at minimum, sufficient to accommodate a path, given the existing terrain, the center of which is at least 20 feet from any property line.
(2) Pedestrian and multi-purpose paths. Greenspaces should provide for pedestrian and/or multi-use paths, not less than eight feet wide. Motorized vehicles should not be permitted on trail systems except for maintenance, construction, or public safety purposes. Where appropriate and convenient, such pedestrian and multi-purpose paths should be made handicapped accessible.
(3) Path/street crossings. Where greenspace path systems cross and internal subdivision street, the access points should be directly across from each other, clearly identified both to the motorist and pedestrian, and located with appropriate sight distance as determined by the engineer. Where a path crosses any county road, the path should be grade separated (i.e., by tunnel or bridge), or located at a traffic control device and approved by the engineer and director.
Historia
(Ord. of 10-16-01, § 1)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.