Sec. 103-22. Prohibited construction for residential buildings.
Sobre este texto
- As published by Municode, retrieved 2026-11-23
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
No construction may be initiated within the county for any residential building of any type which unless the following high-efficiency plumbing fixtures are included:
(1) A water closet or toilet that:
a. Is a dual flush water closet that meets the following standards:
1. The average flush volume of two reduced flushes and one full flush may not exceed 1.28 gallons;
2. The toilet meets the performance, testing, and labeling requirements prescribed by the following standards, as applicable:
(i) American Society of Mechanical Engineers Standard A112.19.2-2008;
and (ii) American Society of Mechanical Engineers Standard A112.19.14-2006, Six-Liter Water Closets Equipped with a Dual Flushing Device"; and
3. Is listed to the WaterSense™ Tank-Type High Efficiency Toilet Specification;
or
b. Is a single flush water closet, including gravity, pressure assisted, and electrohydraulic tank types, that meets the following standards:
1. The average flush volume may not exceed 1.28 gallons;
2. The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and
3. The toilet must be listed to the WaterSense™ Tank-Type High Efficiency Toilet Specification;
(2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure;
(3) A urinal and associated flush valve that:
a. Uses no more than 0.5 gallons of water per flush;
b. Meets the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.19.2/CSA B45.1;
c. For flushing urinals, meets all WaterSense™ specifications for flushing urinals;
and
d. Where non-water urinals are employed, complies with American Society of Mechanical Engineers Standard A112.19.3/CSA B45.4 or American Society of Mechanical Engineers Standard A112.19.19/CSA B45.4. Non-water urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where non-water urinals are installed they shall have a water distribution line roughed in to the urinal location at a minimum height of 56 inches (1,422 mm) to allow for the installation of an approved backflow prevention device in the event of a retrofit. Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead ends. Where non-water urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing;
(4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than
1.5 gallons of water per minute at a pressure of 60 pounds per square inch in accordance with American Society of Mechanical Engineers Standard A112.18.1/CSA B.125.1 and listed to the WaterSense™ High-Efficiency Lavatory Faucet Specification;
and
(5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more than 2.0 gallons of water per minute.
Historia
(Code 2000, § 14-62; Ord. of 4-1-1991, § 2)