81.1. Table of requirements by district and use. Within the zoning districts listed herein, the following requirements shall apply except as otherwise provided:
District and Type of Use Minimum Lot Area (sq. ft. per unit)+ Minimum Lot Width Measured at Building Line (ft.)^ Maximum Lot Coverage (%)
TABLE 6
AG-1 Agricultural/Rural District All Permissible Uses:
with septic tank and well 87,120 150 25 with septic tank and water system 87,120 150 25 with sewer and water system 87,120 150 25 AG-R Agricultural/ Residential District
All Permissible Uses:
with septic tank and well 87,120 100 25 with septic tank and water system 87,120 100 25 with sewer and water system 87,120 100 25 M-2 General Industrial District
All Permissible Uses and Uses authorized by permit:
with septic tank and well** 43,560 150 65 with septic tank and water
system** 22,500 100 65 with sewer and water system 20,000 80 80 R-R Rural-Residential District
All Permissible Uses:
with septic tank and well 43,560* 150 25 with septic tank and water system 22,500* 100 25 with sewer and water system 20,000* 100 25 District and Type of Use
Minimum Lot Area (sq. ft. per unit)+ Minimum Lot Width Measured at Building Line (ft.)^ Maximum Lot Coverage (%) R-1 Single-Family Residential District All Permissible Uses:
with septic tank and well 43,560* 150 20 with septic tank and water system 22,500* 100 20 with sewer and water system 20,000 100 20 R-1A Single-Family Residential District
All Permissible Uses:
with septic tank and well 43,560* 150 20 with septic tank and water system 22,500* 100 20 with sewer and water system 13,000 80 25 R-2 Two-Family Residential District
Single-Family Dwelling:
with septic tank and well 43,560* 150 25 with septic tank and water system 15,000* 100 25 with sewer and water system 13,000 80 25 Single-Family Attached Dwelling:
with sewer and water system 2,000 1,2 20 30 Two-Family Dwelling (Duplex)
with septic tank and well 43,560* 150 25 with septic tank and water system 10,000* 100 25 with sewer and water system 8,000 85 25
Other Permissible Uses:
with septic tank and well 43,560* 150 25 with septic tank and water system 15,000 100 25 with sewer and water system 13,000 100 25
TABLE 7
R-3 Multifamily Residential Single-Family Dwelling:
with septic tank and well 43,560* 150 30 with septic tank and water system 15,000* 100 30 with sewer and water system 13,000 85 30 Two-Family Dwelling:
with septic tank and well 43,560* 150 30 with septic tank and water system 10,000* 100 30 with sewer and water system 8,000 85 30
Single-Family Attached Dwelling: 2,000 1,2 20 30 Multifamily Dwelling: 2,000 1,2 85 30
Other Permissible Uses:
District and Type of Use Minimum Lot Area (sq. ft. per unit)+ Minimum Lot Width Measured at Building Line (ft.)^ Maximum Lot Coverage (%) with septic tank and well 43,560* 150 30 with septic tank and water system 15,000 100 30 with sewer and water system 13,000 85 30
TABLE 8
R-MH Manufactured Home Residential District Manufactured Home Parks Section 91.2
Manufactured Homes:
with septic tank and well 43,560* 150 25 with septic tank and water system 22,500* 100 25 with sewer and water system 15,000 85 25 Single-Family Dwelling:
with septic tank and well 43,560* 150 25 with septic tank and water system 22,500* 100 25 with sewer and water system 15,000 85 25 Other Permissible Uses:
with septic tank and well 43,560* 150 25 with septic tank and water system 22,500* 100 25 with sewer and water system 15,000 85 25 R-1-R Single-Family Rural-Residential District with septic tank and well 87,120 150 25
with septic tank and water system 87,120 100 25 with sewer and water system 87,120 100 25 C-1 Neighborhood Commercial District
with septic tank and well 43,560* 150 50 with septic tank and water system 15,000* 100 50 with sewer and water system 3,500 30 80
C-2 General Commercial District with septic tank and well 43,560* 150 50 with septic tank and water system 15,000* 100 50 with sewer and water system 3,500 30 80
C-3 Entertainment Commercial District See section 99
TABLE 9
M-1 Light Industrial District All Permissible Uses:
with septic tank and well 43,560 150 50 with septic tank and water system 15,000 100 50 with sewer and water system 10,000 75 80 District and Type of Use
Minimum Lot Area (sq. ft. per unit)+ Minimum Lot Width Measured at Building Line (ft.)^ Maximum Lot Coverage (%) PUD Planned Unit Development District See section 102
* See section 85 for lot size modifications based on ground water pollution susceptibility.
**unless utility connection required by sec. 74.23.
+ except as otherwise required by sec. 74.23(1).
^+ as to data centers, as set forth in use permit conditions.
1 The developer of single-family attached and multifamily dwellings is required to set aside an additional 4,000 square feet of common open space for each dwelling unit. This area cannot be used for any other purpose except as open space. See section 92.
2 When located adjacent to arterial or collector streets, minimum lot width measured at the property line facing said street shall be at least 100 feet.
Historia
(Ord. No. 201203-2o, 3-20-2012; Ord. of 6-5-2018; Res. of 1-16-2026, § 1, 1-16-2026)