(a) Requirement for pollution susceptibility area. For all pollution susceptibility areas, new waste disposal facilities must have synthetic liners and leachate collection systems.

(b) New agricultural waste impoundment sites. New agricultural waste impoundment sites shall be lined if they are within:

(1) A high pollution susceptibility area;

(2) A medium pollution susceptibility area and exceed 15 acre-feet; or

(3) A low pollution susceptibility area and exceed 50 acre-feet.

At a minimum, the liner shall be constructed of compacted clay having a thickness of one-foot, and a vertical hydraulic conductivity of less than 5 by 10-7 cm/sec or other criteria established by the U.S. Department of Agriculture Natural Resources Conservation Service.

(c) Land disposal of municipal/household solid waste or hazardous waste. Land disposal of municipal/household solid waste or hazardous waste shall not be permitted within any significant groundwater recharge area.

(d) Handling of hazardous materials in significant groundwater recharge areas. For all significant groundwater recharge areas, the handling, storage and disposal of hazardous materials, as identified in section 312 of the Resource Conservation and Recovery Act of 1976, as amended (42 USC 6901 et seq.), excluding underground storage tanks, and in amounts of 10,000 pounds or more on any one day, shall take place on an impermeable surface having spill and leak protection approved by the state department of natural resources, environmental protection division, and in conformance with local fire prevention code requirements.

(e) Aboveground chemical or petroleum storage tanks. For all significant groundwater recharge areas new, aboveground chemical or petroleum storage tanks larger than 650 gallons must have secondary containment for 110 percent of tank volume, or 110 percent of the largest tank in a cluster of tanks. Such tanks used for agricultural purposes are exempt from this requirement, provided they comply with applicable federal regulations.

(f) New wastewater treatment basins in high pollution susceptibility areas. For high pollution susceptibility areas, new wastewater treatment basins shall have an impermeable liner approved by the state department of natural resources, environmental protection division.

(g) Stormwater infiltration basins. For high pollution susceptibility areas, no new stormwater infiltration basins may be constructed.

(h) Wastewater spray irrigation systems and land application of wastewater sludge. For high pollution susceptibility areas, the use of wastewater spray irrigation systems and the land application of wastewater sludge shall be practiced in accordance with state department of natural resources criteria for slow rate land treatment. An application for a development permit for activities involving wastewater spray irrigation or land application of wastewater sludge must be accompanied by proof that the applicant has received a land application system permit from the state department of natural resources, environmental protection division.

(i) Minimum lot sizes and septic systems generally. Construction shall not proceed on any building or structure to be served by an on-site sewage management system until the county health department approves the proposed sewage management system as meeting requirements outlined in section M of the state department of human resources (DHR) manual for on-site sewage management systems, incorporated herein by reference, and the required building permits have been issued.

(j) Minimum lot size requirements in areas of significant groundwater recharge.

(1) The following minimum lot size requirements apply to on-site sewage management systems in areas of significant groundwater recharge. Minimum lot sizes shall be based on application of table MT-1 of the referenced DHR manual:

a. 150 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1 if they are within a high pollution susceptibility area;

b. 125 percent of the subdivision minimum lot size calculated based on application of DHR Table MT-1 if they are within a medium pollution susceptibility area;

c. 110 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1 if they are within a low pollution susceptibility area.

(2) The minimums set forth in subsections (j)(1), (2) and (3) of this section may be increased based on consideration of factors such as those enumerated in section M of the state department of human resources manual for on-site sewage management systems, paragraphs 1A-1F.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 11-13-2001, § 6)