Pulaski County · Código de ordenanzas
Appendix A - SUBDIVISION ORDINANCE / Chapter 5 - CONFORMANCE WITH COMPREHENSIVE PLAN, IMPROVEMENTS REQUIRED, DESIGN AND CONSTRUCTION STANDARDS FOR ALL SUBDIVISIONS / 5.0 - Conformance With Comprehensive Plan and Other Regulations.
Section 5.2.12. Selection Guidelines for Storm Sewer Piping.
Sobre este texto
- As published by Municode, current through 2023-06-05
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Type of Pipe Installation Reinforced Concrete Pipe (RCP) Corrugated Steel AASHTO M-36 Corrugated Aluminum
AASHTO
M-196 Plastic
AASHTO
M-294 Reinforced Concrete Box Culvert Per
GADOT
Standards Aluminized Type
II CMP
Bituminous Coated CMP Aluminum Alloy
CMP
Corr. High Density Polyethylene Smooth Lined Longitudinal Grade < 10% Yes Yes Yes Yes Yes (1) NA Longitudinal Grade > 10% No Yes Yes Yes Yes (1) NA Cross Drain <
250 ADT
Yes Yes Yes Yes Yes (1) NA Cross Drain >
250 ADT
Yes No No No No NA Cross Drain Flowing Stream Appl.
Yes 3 No Yes Yes (1) (4) NA Cross Drain 25 Yr. Flow > 200 CFS or Fill Depth > 18 ft.
2 No No No No Yes Conditional Uses:
1. Corrugated high-density polyethylene pipe, smooth lined type "S", must be manufactured and installed in strict compliance with the manufacturer's recommendation. Special backfill and bedding are required per the direction of the County Roads Superintendent. Prior approval of the County Roads Superintendent is required. HDPE applications shall not exceed 36" diameter.
2. Reinforced concrete box culverts are required under excessive flow and/or fill depth conditions.
Approved pipe materials may be utilized in some instances, based on the County Roads Superintendent's assessment of existing conditions and future maintenance requirements.
3. The addition of Type "A" full bituminous coating, with paved invert, is required for this application. (AASHTO M-190)
4. Requires approval of County Roads Superintendent based on assessment of existing conditions and future maintenance requirements.
Section 5.3 Design Standards.
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.