More stringent design and construction standards may be required by the County Roads Superintendent where streets cross one hundred (100) year floodplains, serve as the only means of public ingress and egress to one or more lots, cross flowing streams, cross poor soils, or encounter similar conditions.

In general, all streets, roads, and alleys shall be constructed to provide the necessary paving, roadway, drainage, and safety requirements as provided herein and by other specifications of the Sole County Commissioner.

All streets, roads, and alleys shall be graded to their full width so that pavement, shoulders, and sidewalks, where required or proposed for future installation, can be constructed on a uniform plane. The right-of-way shall be cleared of all trees. Additional trees shall be removed outside of the right-of-way if they are under the drip line of any tree in the right-of-way as directed by the County Roads Superintendent or Enforcement Officer.

Clearing, grading, or other land-disturbing activities associated with subdivision construction shall not commence until the preliminary plat, engineered construction plans, and soil erosion and sediment control plans have all been approved by Pulaski County. This shall not be construed to prohibit necessary logging or survey operations prior to approval of such plans.

An adequate system for storm drainage based upon at least a twenty-five (25)-year storm event shall be provided for the proper drainage of all surface water originating in or affecting the subdivision. Storm water inlets shall be designed and located so as to not exceed a maximum gutter spread width of six feet (6') based on flow data calculations for the ten (10)-year storm event.

The drainage system shall conform to any County storm drainage master plan which may be adopted and shall include necessary curbing, pipes, culverts, headwalls, drop inlets, bridges, swale ditches, or any other type of drainage facility need to control the flow of water in, around, or through the subdivision.

Pipe size will be determined by utilizing the Rational Method or the Soil Conservation Method (TR-55) to compute peak runoff, with all measurements conforming to all specifications set forth in Section 5.2.8 of this Ordinance. A twenty-five (25)-year storm event will be used to determine all pipe sizes. All cross drains and culverts under roadways shall be sized based on a fifty (50)-year storm event.

All proposed piping within a FEMA identified floodplain shall be sized to adequately convey the one hundred (100)-year frequency storm event.

Manning's equation shall be used to evaluate hydraulic capacity and velocity of flow within the storm drainage system. Required storm pipes shall be designed to maintain a water flow velocity greater than or equal to three feet per second (3'/sec.). The hydraulic analysis of culverts shall be based on Federal Highway Administration engineering practice and take into account the inlet geometry, slope, size, roughness, and approach or tailwater conditions. Storm water inlets shall be designed in accordance with Federal Highway Administration engineering practice and constructed in compliance with GADOT construction standards and shall be GADOT Standard 1033, 1034, and 1011. Drainage calculations and design data are required for all storm water conveyance systems and structures. All drainage structures shall be constructed of reinforced precast concrete, four-foot (4') diameter or larger. All 1033D and 1034 D drainage structures shall require a reinforced precast "Round to Square" adapter for additional throat support. All junction boxes shall include approved steps, spaced twelve inches (12") o.c. vertically, to allow safe access by maintenance personnel. All structures shall have paved inverts.

In certain circumstances where rolled or "hollywood" curb is utilized, the County Roads Superintendent may require the use of 1033F and 1034F catch basins.

Energy dissipation devices, such as splash pads, rip rap, stilling basins, etc., shall be provided at the outlet of every culvert and piped discharge system. The size and type of energy dissipation device to be used shall be designed in accordance with sound engineering practices and the requirements of this Ordinance.

All drainage ditches that are between building lots shall be piped a minimum of at least one hundred feet (100') from the front building line. This shall be done at the expense of the developer.

Additional requirements for storm water management and detention facilities are outlined in Section

5.7 of this Ordinance.