(a) Waste disposal facilities and synthetic liners. For all pollution susceptibility areas, new waste disposal facilities must have synthetic liners and leachate collection systems.

(b) Requirements for agricultural compounds. New agricultural waste impoundment sites shall be lined if they are within a:

(1) High pollution susceptibility area;

(2) Medium pollution susceptibility area and exceed 15 acre-feet; or

(3) Low pollution susceptibility area and exceed 50 acre area-feet.

As a minimum, the liner shall be constructed of compacted clay having a thickness of one foot and a vertical hydraulic conductivity of less than 5 × 10-7 cm/sec or other criteria established by the United States Department of Natural Resource and Conservation Service.

(c) Hazardous waste disposal facilities. No land disposal of hazardous waste shall be permitted within any significant groundwater recharge area.

(d) Hazardous waste handling and storage. New facilities that handle hazardous materials of the types listed in section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage tanks) and in amounts of 10,000 pounds or more on any one day shall perform their operations on impervious surfaces and in conformance with any applicable federal spill prevention requirements and local fire code requirements.

(e) Aboveground chemical and petroleum storage tanks. For all significant groundwater recharge areas, new aboveground chemical or petroleum storage tanks having a minimum of 660 gallons must have secondary containment for 110 percent of tank volume or 110 percent of the largest tanks in a cluster of tanks.

(f) Wastewater treatment facilities. For high pollution susceptibility areas, new wastewater treatment basins shall have an impermeable liner approved by EPD.

(g) Stormwater infiltration basins. For high pollution susceptibility areas, no new stormwater infiltration basins may be constructed.

(h) Wastewater spray irrigation systems. For high pollution susceptibility areas, wastewater spray irrigation systems or the land spreading of wastewater sludge shall be practiced in accordance with department of natural resources criteria for slow rate land treatment. An application for a development permit for activities involving wastewater spray irrigation or land spreading of wastewater sludge must be accompanied by proof that the applicant has received a land application system permit from EPD.

(i) Minimum lot sizes for new homes. New homes served by septic tank/drain systems shall be on lots having the following minimum size limitations as follows, based on application of table MT-1 of the state department of human resources' manual for on-site sewage management systems (hereinafter DHR table MT-1). The minimums set forth in table MT-1 may be increased further based on consideration of other factors (set forth in sections A through F) of the DHR manual.

(1) 150 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1 if they are within a high pollution susceptibility area;

(2) 125 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1 if they are within a medium pollution susceptibility area; and

(3) 110 percent of the subdivision minimum lot size calculated based on application of DHR table MT-1 if they are within a low pollution susceptibility area.

(j) Minimum lot sizes for new mobile home parks. New mobile home parks served by septic tank/drain systems shall be on lots having the following minimum size limitations as follows, based on application of table MT-2 of the state department of human resources' manual for on-site sewage management systems (hereinafter DHR table MT-2). The minimums set forth in table MT-2 may be increased further based on consideration of other factors (set forth in sections A through F) of the DHR manual.

(1) 150 percent of the subdivision minimum lot or space size calculated based on application of DHR table MT-2 if they are within a high pollution susceptibility area;

(2) 125 percent of the subdivision minimum lot or space size calculated based on application of DHR table MT-2 if they are within a medium pollution susceptibility area; and

(3) 110 percent of the subdivision minimum lot size calculated based on application of DHR table MT-2 if they are within a low pollution susceptibility area.