(1) The subdivider/developer shall provide adequate stormwater drainage in accordance with these regulations. The subdivider/developer shall also provide for adequate drainage all surface water drainage.
(2) The drainage system for a subdivision, residential, commercial, or manufacturing, shall be designed in accordance with sound engineering principles and procedures such that all marketable lots or parcels upon the plat are
positively drained.
(3) The drainage system shall be designed to accommodate drainage from adjacent lots or parcels which naturally drain to or through the lands being subdivided. The drainage system shall be designed such that it does not affect the natural drainage onto adjacent parcels unless an agreement is obtained by the developer/subdivider from the owner of such adjacent parcels. A copy of any such agreement shall be submitted to the Whitfield County Engineer.
(4) Drainage facilities which are designed to accommodate flowing waters shall be hydraulically designed to function when subjected to the maximum flow rate which may be expected to
occur no more often than once in ten years.
(5) Drainage facilities which are designed to handle water accumulations shall be designed to accommodate the maximum water level which may be expected to occur no more often than once in 25 years. Necessary drainage facilities including, but not limited to, culverts, rights-ofway, and easements, shall be offered for dedication to Whitfield County.
(6) All drainage systems discharging into any state waters, including but not limited to wetlands, as determined by the U.S. Army Corps of Engineers, shall pass through an approved sedimentation and detention pond prior to such discharge.
(7) A master drainage plan shall be submitted to the Whitfield County Engineer simultaneously with the submittal of a preliminary plat.
Historia
(Ord. of 9-24-01, § 3-3; Res. of 5-13-02)
Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.